14.10 KBEP-240D Electronic Potentiometer (Part No. 9108) – Provides digital type control of motor speed.

Replaces a standard rotary potentiometer with a set of customer supplied momentary push buttons or

membrane switches. Operates on 115 or 230 Volt AC line input.

14.11 KBET-240D Electronic Tachometer (Part No. 9469) – Provides an isolated tack-feedback signal and an

isolated voltage follower signal from an open collector (Hall, magnetic, inductive, optical) or 2-wire inductive

pickup (encoder). Operates on 115 or 230 Volt AC line input

14.12 RFI Filters – Provide RFI and EMI suppression. Complies with CE Council Directive 89/336/EEC relating to

the Class A Industrial Standard and Class B Residential Standard. Filters are available in remote or under-

mount types. See Table 7.

31

Model

Part No.

Current Rating

(RMS Amps)

Mounting

Class

KBRF-200A

9945C

24

Remote

A - Industrial

KBRF-250

9509

10

Undermount

A - Industrial

KBRF-300

9484

16

Remote

B - Residential *

KBRF-350

9511

10

Undermount

B - Residential *

TABLE 7 – RFI FILTER SELECTION

* Also meets Industrial Standard.