3.0 Preoperational Procedures

3.1

Fill Gear Box with Oil

3.1.1

CAUTION

DO NOT use any oil or quantity other than that listed below.

3.1.2

For a new hoist the correct quantity and type of oil is supplied with the hoist in separate containers.
Remove the fill plug from the top of the hoist and connect the flexible pour tube to the oil container.
Pour in all of the oil from the separate containers, then replace the fill plug.

3.1.3 Refer

to

Section 6.2

of the EROM when replacing the gear oil or checking the gear oil level.

Table 3-1

Amount of Gear Oil

Capacity

Code

Quarts

Liters

080S, 100L

3.17

3.0

100S, 150S,

200S

6.34

(3.17 per

hoist body)

6.0

(3.0 per

hoist body)

Figure 3-1 Oil Plug Locations

ER Gear Oil:

§ Harrington standard: Antoil super B (NIPPON OIL)

§ Acceptable equivalent: Meropa No.68 (TEXACO)

3.2 Chain

3.2.1

The quantity and location of the chain components including chain springs and stoppers depends on
the hoist model and capacity. Never operate the hoist with incorrect, missing or damaged chain
components. Refer to the hoist's nameplate,

Table 3-2

, and

Figure 3-2

and ensure that all chain

components are in the correct location and properly installed.

3.2.2

When the hoist is used without a chain container, the free end of the chain is attached to the hoist body
as shown in

Figure 3-2

. Connect the “no load” end of the chain to Chain Guide A and the pre-installed

socket bolt and lock nut. Make sure the chain remains free of twists and the chain Stopper is installed
on the correct link. Refer to

Table 3-2

for proper placement of Stopper.