Chapter 4: basic management tasks, Displaying system information, 2 basic management tasks – Asante Technologies 40240/40480-10G User Manual
Page 77

Web – Click System, System Information. Specify the system name, location, and
contact information for the system administrator, then click Apply. (This page also
includes a Telnet button that allows access to the Command Line Interface via Telnet.)
Figure 4-1 System Information
CLI – Specify the hostname, location and contact information.
Console(config)#hostname R&D 5
23-1
Console(config)#snmp-server location WC 9
24-4
Console(config)#snmp-server contact Ted
24-4
Console(config)#exit
Console#show system
23-7
System Description: 24/48 port 10/100/1000 Stackable Managed Switch with
2 X 10G
uplinks
System OID String: 1.3.6.1.4.1.259.8.1.9
System Information
System Up Time:
0 days, 1 hours, 28 minutes, and 0.51 seconds
System Name:
R&D 5
System Location:
WC 9
System Contact:
Ted
MAC Address (Unit1):
00-20-1A-DF-9C-A0
MAC Address (Unit2):
00-20-1A-DF-9E-C0
Web Server:
Enabled
Web Server Port:
80
Web Secure Server:
Enabled
Web Secure Server Port: 443
Telnet Server:
Enable
Telnet Server Port:
23
Authentication Login:
Local RADIUS None
Jumbo Frame:
Disabled
Jumbo Frame Size:
1522
POST Result:
DUMMY Test 1 ................. PASS
DRAM Test .................... PASS
Timer Test ................... PASS
PCI Device 1 Test ............ PASS
I2C Bus Initialization ....... PASS
Fan Speed Test ............... PASS
Done All Pass.
Console#
4-2
Basic Management Tasks
4