Ransburg – Ransburg Voltage Master 2 78789_LEPS5001 User Manual
Page 40

NOTES
:
1. With voltage turned OFF, disconnect the high
voltage output cable(s) from the power supply
tank. Inspect the high voltage cable end for
contamination or any unusual signs of wear such
as pitting or discoloration. Clean or replace as
necessary.
2. Turn high voltage ON while the high voltage
cables are still disconnected. If there is still a
problem with high voltage or overloads then re-
fer to the troubleshooting guide, otherwise, if the
power supply now seems to be operating properly,
continue to the next step.
3. If multiple applicators are connected to the
power supply through a high voltage junction tank,
then reconnect the high voltage cable from the
power supply output to the junction tank. Now
disconnect each high voltage output cable from
the junction tank to the applicators. Again, inspect
each cable end for obvious signs of contamination
or wear.
4. Turn high voltage ON. If the high voltage is
now operating correctly, then try connecting one
applicator (or station) at a time to the junction tank
in order to isolate the problem to a specific output.
5. Once a specific HV output is identified as caus-
ing the problem, then perform system maintenance
and diagnosis. This may include replacing the high
voltage cable(s) or junction tank as appropriate.
Voltage Master 2 - Maintenance
36
Ransburg
CP-02-02.6