beautypg.com

Ransburg – Ransburg Voltage Master 2 78789_LEPS5001 User Manual

Page 40

background image

NOTES

:

1. With voltage turned OFF, disconnect the high

voltage output cable(s) from the power supply

tank. Inspect the high voltage cable end for

contamination or any unusual signs of wear such

as pitting or discoloration. Clean or replace as

necessary.

2. Turn high voltage ON while the high voltage

cables are still disconnected. If there is still a

problem with high voltage or overloads then re-

fer to the troubleshooting guide, otherwise, if the

power supply now seems to be operating properly,

continue to the next step.

3. If multiple applicators are connected to the

power supply through a high voltage junction tank,

then reconnect the high voltage cable from the

power supply output to the junction tank. Now

disconnect each high voltage output cable from

the junction tank to the applicators. Again, inspect

each cable end for obvious signs of contamination

or wear.

4. Turn high voltage ON. If the high voltage is

now operating correctly, then try connecting one

applicator (or station) at a time to the junction tank

in order to isolate the problem to a specific output.

5. Once a specific HV output is identified as caus-

ing the problem, then perform system maintenance

and diagnosis. This may include replacing the high

voltage cable(s) or junction tank as appropriate.

Voltage Master 2 - Maintenance

36

Ransburg

CP-02-02.6