MAINTENANCE

GENERAL

Developing a good preventive maintenance (PM)

program is key to keeping any system operating

properly, the frequency of which is determined by

each individual installation. Contact your Rans-

burg representative or the Service department

for guidelines or assistance for establishing a

preventative maintenance program.

There is very little maintenance for the Control

Panel or the Power Supply tank other than good

housekeeping practices. These include:

1. Keeping the control panel door closed at all

times. This will maintain the dust-tight environment

required by the electronic printed circuit boards.

2. Plug all unused access holes into the control

panel in order to keep contamination out.

3. Use the following guidelines for cleaning the

Control Panel and Power Supply tank.

• Ensure that the high voltage is OFF and turn

OFF the power source to the

Control Panel.

• Clean the exterior with a clean, dry, lint-free

cloth. If necessary, isopropyl alcohol or other

mild cleaning solutions can be used.

• Open the panel door and clean internally by

using a stream of clean, dry factory air to remove

any traces of moisture and foreign matter.

• Check interior for evidence of contamination

from either moisture or foreign matter.

• Visually inspect components. Look for loose

wiring connections and for visible evidence of

component deterioration.

• Restore the unit to operation.

>

Electrical shock hazard. ALWAYS turn

power OFF prior to cleaning or servicing

any part of the system. Failure to do so

could result in serious injury or death.

>

Whenever removing high voltage

cable(s) from equipment, ground the plug

end of the cable(s) by contacting the plug

to electrical ground. Do not touch the

plug until it has been grounded. This will

eliminate the possibility of residual charge

causing electrical shock.

>

Whenever the high voltage cable is

removed from the Power Supply tank,

ALWAYS discharge any residual electrical

charge from the power supply by attaching

an appropriate ground wire to the grounded

power supply container and then inserting

it down the free end of the high voltage

output tube.

>

To ensure continuous, efficient, trou-

ble-free operation of the Power Supply and

to extend its service life, keep the exterior

clean and dry. It is also very important to

keep the areas around the high voltage

cable connections clean to protect against

static discharges.

W A R N I N G

!

Voltage Master 2 - Maintenance

33