Ransburg, Input power, Location – Ransburg Voltage Master 2 78789_LEPS5001 User Manual

Page 18: Safety ground

background image

>

The 78789 control panel and the

LEPS5001 power supply MUST be located

outside the hazardous area (see NFPA-33).

>

This manual MUST be read and thor-

oughly understood by ALL personnel who

operate, clean, or maintain this equipment.

Special care should be taken to ensure that

the WARNINGS and requirements for oper-

ating and servicing safely, are followed.

W A R N I N G

!

Install the control panel in a convenient area

outside the hazardous location, where it will be

protected from the possibility of any contact with

water, vapor or high humidity, and ambient tem-

peratures in excess of 120

o

F. The area should

be clean, dry, and well ventilated.

Locate the power supply tank in a convenient

area as close to the applicator(s) as possible

in order to minimize the amount of high voltage

cable required.

INPUT POWER

The AC Input power routing and connections to the

control panel should be supplied from a

FUSED

DISCONNECT and should meet all applicable

National Electrical Code (NEC) guidelines and

any other requirements as suitable for the location.

LOCKOUT/ TAGOUT procedures should be put

in place for the fused disconnect. Using conduit,

route the input power wiring through the AC power

opening in the top left corner of the control panel.

For greatest noise immunity the AC input should

be located as close as possible to the AC line filter

(see Figure 4). For this reason, it is recommend-

ed that the AC input

not be relocated to another

position on the control panel. Route the input

wiring through the conduit and attach to terminal

block TB7 as shown in Figure 4.

LOCATION

>

Do not locate the control panel or

power supply near or adjacent to heat

producing equipment such as ovens, high

wattage lamps, steam pipes, etc.

C A U T I O N

!

SAFETY GROUND

Control Panel

Ground the control panel by mounting to structural

steel that is at earth ground potential. If this is not

possible, ground the control panel by connecting

the supplied ground wire assembly from the control

panel ground stud to the nearest true earth ground

(structural steel, pipes, or driven ground rod). For

maximum protection from electrical noise make

this connection as short as possible.

Power Supply Tank

Ground the power supply tank by connecting the

supplied ground wire assembly from the power

supply ground stud to the nearest true earth ground

(structural steel, pipes, or driven ground rod). For

maximum protection from electrical noise make

this connection as short as possible.

>

To shorten the ground wire assembly,

use a screwdriver to remove the lug (at end

opposite clamp) from the end of the assem-

bly, cut the wire to the length needed, strip

insulation 1" from cut and reattach the lug.

NOTE

>

Ensure that the control panel and

power supply tank are properly ground-

ed to a true earth ground as described

above.

C A U T I O N

!

Voltage Master 2 - Installation

14

Ransburg