EUROPEAN ATEX DIRECTIVE 94/9/EC, ANNEX II, 1.0.6

The following instructions apply to equipment

covered by certificate number Sira 08ATEX5040X:

1. The equipment may be used with flammable

gases and vapors with apparatus groups II and

with temperature class T6.

2. The equipment is only certified for use in am-

bient temperatures in the range +12.8°C to +40°C

and should not be used outside this range.

3. Installation shall be carried out by suitably

trained personnel in accordance with the applicable

code of practice e.g. EN 60079-14:1997.

4. Inspection and maintenance of this equipment

shall be carried out by suitably trained personnel

in accordance with the applicable code of practice

e.g. EN 60079-17.

5. Repair of this equipment shall be carried out

by suitable trained personnel in accordance with

the applicable code of practice e.g. EN 60079-19.

6. Putting into service, use, assembling, and

adjustment of the equipment shall be fitted by

suitably trained personnel in accordance with the

manufacturer's documentation.

Refer to the "Table of Contents" of this service

manual:

a. Installation

b. Operation

c. Maintenance

d. Parts Identification

7. Components to be incorporated into or used

as replacement parts of the equipment shall be

fitted by suitably trained personnel in accordance

with the manufacturer's documentation.

8. The certification of this equipment relies upon

the following materials used in its construction:

If the equipment is likely to come into contact with

aggressive substances, then it is the responsibility

of the user to take suitable precautions that prevent

it from being adversely affected, thus ensuring that

the type of protection provided by the equipment

is not compromised.

Aggressive substances: e.g. acidic liquids or

gases that may attack metals, or solvents that

may affect polymeric materials.

Suitable precautions: e.g. regular checks as

part of routine inspections or establishing from

the material's data sheets that it is resistant to

specific chemicals.

Refer to "Specifications" in the "Introduction"

section:

a. All fluid passages contain stainless steel

or nylon fittings.

b. High voltage cascade is encapsulated with

a solvent resistant epoxy.

9. A recapitulation of the certification marking is

detailed in the "Atex" section, on the next page,

drawing numbers: 78886 and 78894-04.

10. The characteristics of the equipment shall

be detailed e.g. electrical, pressure, and voltage

parameters.

The manufacturer should note that, on being put

into service, the equipment must be accompanied

by a translation of the instructions in the language

or languages of the country in which the equip-

ment is to be used and by the instructions in the

original language.

Voltage Master 2 - Atex

6

Ransburg