TB2-3 to TB2-5

TB2-8, TB2-8A, TB2-9, TB2-10

TB2-12, TB2-13, TB2-14

TB2-15
TB2-20
TB3-58
TB3-59
TB3-60
TB3-63
TB3-64
TB3-65

TABLE 2 - ELECTRICAL SYSTEM CONNECTIONS

External HV ON (PLC or Panel Switch)
External HV OFF/RESET (PLC or Panel Switch)
External System Interlocks (Exhaust Air, Conveyor, Reciprocator,
etc.)
External Alarm
DC Pump Control Output
kV Setpoint IN (0-10 VDC = 0-100 kV)
kV Setpoint IN (4-20 ma = 0-100 kV)
Actual kV OUT (0-10 VDC = 0-100 kV)
OL Setpoint IN (0-10 VDC or 4-20 ma = 0-1500 µa)
Actual Current OUT (0-10 VDC or 4-20 ma = 0-2000 µa)
Actual kV OUT (4-20 ma = 0-100 kV)

Description

Terminal Number

White

Black
Black

Red

Bare

TABLE 1 - POWER SUPPLY CONNECTIONS

Wire #

1

17
31
34

Shield

Color

TB4-1

TB4-17
TB4-31
TB4-34

TB4-GND

To Control Panel

PS1
PS2
PS3

SOL1

TABLE 3 - PNEUMATIC SYSTEM CONNECTIONS

External HV ON
External HV OFF/RESET
External Interlock
HV ON Output (Normally used for Air Logic Station HV ON indicator)

Description

Terminal Number

Voltage Master 2 - Installation

18

Ransburg

CP-02-02.6