GENERAL DESCRIPTION

The

Voltage Master 2 high voltage power

supply system includes a control panel and power

supply unit in combination to produce up to 100kV

DC continuous operating voltage while delivering

up to 1,500 microamps load current. This heavy

duty, high power system provides for rugged and

reliable operation in a variety of industrial finish-

ing applications. The Voltage Master 2 system

also includes the necessary system interfaces for

complete remote control and monitoring functions.

Voltage Master 2 systems can include, but are

not limited to, the following:

Power Supply Control Panel

The control panel contains all of the necessary

control circuitry, operator interface controls and

remote I/O interfaces. A single cable connects the

control panel to the power supply unit.

LEPS5001 HV Power Supply Tank

The power supply tank contains the high voltage

transformer, voltage multiplier, and other compo-

nents necessary to generate a high voltage output

and to return actual voltage and current feedback

signals to the control panel. All components of the

power supply were design selected for reliable,

heavy duty service. The components, including

the high voltage transformer, operate immersed

in high quality (non-pcb) dielectric oil for electrical

insulation and to provide heat dissipation. The

power supply is supplied as a separate unit in order

that it can be installed as close to the applicators

as possible. This minimizes the amount of high

voltage cable and routing hardware, resulting in

improved system safety and reliability.

HV Junction Tanks

High voltage junction tanks receive an input from

the power supply, split the input, and provide

multiple outputs. Each junction tank output can

be connected to a single applicator or station

of applicators. The internal components of the

each junction tank are immersed in high quality

INTRODUCTION

(non-pcb) dielectric oil. Consult the appropriate

junction tank service manual or your authorized

Ransburg representative for further information.

HV Cable

The Ransburg high voltage cable is specially

formulated and constructed to offer a maximum

level of dielectric protection while maintaining a

small diameter and bending radius for easy routing.

Remote Pneumatic ON/OFF Switch Station

This is provided to serve as a simple, industrial

ON/OFF control that can be located at the system

operator stations in a convenient location, includ-

ing classified areas. (Contact your Ransburg

representative or Ransburg customer service for

details.)

Air Logic Stations

These standard system panels include all of the

necessary controls for disk or bell system inte-

gration. (Contact your Ransburg representative

or Ransburg customer service for details.)

The Voltage Master 2 system supplies a high de-

gree of safety by continuously monitoring the output

current and rapidly de-energizing high voltage in

the event that the user selected maximum output

current level (overload setting) is exceeded. The

safety circuit is sufficient to eliminate most possible

arcing conditions,

however, the overload current

setting must be properly set as described in

"Overload Adjustment Procedures" in the

"Operation" section of this manual, to ensure

safe operation.

The Voltage Master 2 system, with control panel

78789-02, is listed by Factory Mutual for use with

Voltage Master 2 - Introduction

8

Ransburg

CP-02-02.6