Ransburg, Transformer assembly replacement, Low voltage cable replacement – Ransburg REA Automatic Applicators 77359, 76110, 77140 User Manual
Page 43: Low voltage cable connector assembly
W A R N I N G
!
>
Turn
OFF all power, air, and fluid at the
source.
TRANSFORMER
ASSEMBLY
REPLACEMENT
(REA 9000R AND 900A)
1. Remove the low voltage cable connector from
the transformer by removing the scew and pull
STRAIGHT out of the chamber.
2. Remove the barrel/cascade assembly. (See
“Barrel Assembly Removal” in the “Maintenance”
section.)
3. Remove the fiberglass screw.
4. Slide transformer backward and upward out
of body channel.
C A U T I O N
!
> The low voltage cable
MUST be removed
before removing the transformer assembly.
NOTE
> Generously lubricate transformer
assembly base and body channel with
LSCH0009-00 dielectric grease.
5. Slide replacement transformer into channel of
automatic body.
6. Place gasket in position.
7. Replace the barrel/cascade assembly. (See
“Barrel Assembly Removal in the “Maintenance”
section.)
8. Install low voltage cable connector by matching
the hole on the connector and the transformer, and
pushing the connector
straight into the chamber.
9. Secure in place with screw.
LOW VOLTAGE CABLE
REPLACEMENT
(REA 9000R)
1. Remove applicator from robot.
2. Remove rear mounting plate from fobot.
3. Using a wrench on connector flats, disconnect
low voltage cable from connector assembly.
4. Replace cable in robot arm.
5. Connect new cable to connector assembly
using a wrench on the connector flats to tighten.
C A U T I O N
!
>
DO NOT overtighten low voltage cable
connection to spray applicator, as damage to
plastic parts may occur.
LOW VOLTAGE CABLE
CONNECTOR ASSEMBLY
(REA 9000R)
1. Remove applicator from robot.
2. Remove rear mounting plate from fobot.
3. Using a wrench on connector flats, disconnect
low voltage cable from connector assembly.
4. Remove screw from rear mounting plate.
5. Pull connector assembly out of mounting plate.
Ransburg
REA Automatic Applicators - Maintenance
39
AA-99-02.5