Ransburg, Barrel to body assembly, High voltage module assembly replacement – Ransburg REA Automatic Applicators 77359, 76110, 77140 User Manual
Page 35: Low voltage cable replacement

BARREL TO BODY
ASSEMBLY
(REA 9000W)
1. Slide gasket over the rear end of the barrel
assembly. Lightly coat cascade high voltage con-
nections with LSCH0009-00 dielectric grease.
2. Tighten retaining ring with 19749-00 spanner
wrench.
> Nut should be secured hand tight only.
NEVER apply more than 10 lb•ft torque.
C A U T I O N
!
HIGH VOLTAGE MODULE
ASSEMBLY
REPLACEMENT
(REA 9000W Only)
1. Remove the voltage cable from the rear of the
high voltage module assembly.
2. Remove the high voltage module to barrel
mounting bracket.
3. Remove the four (4) 1/4-20 flat head screws
in the top of the probe holder body assembly.
Remove the probe AND body as ONE assembly.
!
> Turn
OFF all power, air and fluid at the source.
W A R N I N G
> The voltage cable
MUST be removed before
removing the high voltage module.
C A U T I O N
!
4. Remove module retaining screw from the top
of the module.
5. Remove the two (2) 1/4-20 screws that attach
the rear bulkhead plate to the high voltage module.
These screws are accessed through holes in the
sides of the bulkhead plate.
6. Pull the high voltage module STRAIGHT out
through the bulkhead plate.
7. Install new high voltage module and assembly
in reverse order.
> Generously lubricate probe body
metal plunger and high voltage module
contact bore with LSCH0009-00 dieletic
grease.
NOTE
LOW VOLTAGE CABLE
REPLACEMENT
(REA 900A Only)
Disassembly:
1. Using wrench on connector flats, disconnect
low voltage cable from connector assembly.
2. Disconnect other end of low voltage cable from
control unit and remove cable from system.
W A R N I N G
> Ensure control unit power is
OFF before dis-
connecting cable from applicator or control unit.
!
Ransburg
REA Automatic Applicators - Maintenance
31
AA-99-02.5