beautypg.com

Ransburg, P-extension removal, P-extension replacement – Ransburg REA Automatic Applicators 77359, 76110, 77140 User Manual

Page 40

background image

Figure 8: Spring Washer Assembly

14. Insert the assembled items through the rear

packing chamber of the barrel/cascade assembly.

15. Screw packing nut into rear of barrel and

secure it with the 19749-00 Spanner Wrench.

C A U T I O N

!

> There

MUST be six (6) spring washer

(alternately faced) or the applicator will

malfunction!

11. Place packing nut onto shaft.

12. Place adjustment nut onto shaft.

13. Insert fluid nozzle into front of barrel and secure

it firmly with the 19749-00 spanner (nozzle) wrench.

C A U T I O N

!

>

DO NOT over-tighten. Over-tightening may

result in stripped threads or cracked barrel.

NOTE

> The packing nut should be tight

enough that the needle shaft moves in

and out with firm resistance.

16. Place the extension valve rod onto shaft and

align the nuts.

17. To adjust 3/8-inch hex nut and extension

valve rod:

a. Push shaft fully forward until needle/

electrode seats in the fluid nozzle.

b. Screw nut clockwise until it runs out of

thread on end of needle shaft.

c. Screw the valve extension rod until the

faces of the nuts are seated against each

other.

P-EXTENSION REMOVAL

(REA 9000R)

1. Remove transformer connecting screw and

remove plug from transformer.

2. Remove two (2) P-extension screws from bot-

tom mounting plate. Pull P-extension away.

3. Remove two (2) nylon screws from body.

4. Gently pull P-extension from body locating

the two (2) spacers.

P-EXTENSION

REPLACEMENT

(REA 9000R)

1. Locate two (2) spacers in the counter bores of

the body.

2. Locate the two (2) spacers in counter bores of

the P-extension.

3. Secure the two (2) nylon screws in the body.

4. Locate the P-extension into the bottom plate

and fasten using two (2) screws.

5. Reinstall P-extension plug in transformer

using screw.

Ransburg

REA Automatic Applicators - Maintenance

36

AA-99-02.5