Figure 8: Spring Washer Assembly
14. Insert the assembled items through the rear
packing chamber of the barrel/cascade assembly.
15. Screw packing nut into rear of barrel and
secure it with the 19749-00 Spanner Wrench.
C A U T I O N
!
> There
MUST be six (6) spring washer
(alternately faced) or the applicator will
malfunction!
11. Place packing nut onto shaft.
12. Place adjustment nut onto shaft.
13. Insert fluid nozzle into front of barrel and secure
it firmly with the 19749-00 spanner (nozzle) wrench.
C A U T I O N
!
>
DO NOT over-tighten. Over-tightening may
result in stripped threads or cracked barrel.
NOTE
> The packing nut should be tight
enough that the needle shaft moves in
and out with firm resistance.
16. Place the extension valve rod onto shaft and
align the nuts.
17. To adjust 3/8-inch hex nut and extension
valve rod:
a. Push shaft fully forward until needle/
electrode seats in the fluid nozzle.
b. Screw nut clockwise until it runs out of
thread on end of needle shaft.
c. Screw the valve extension rod until the
faces of the nuts are seated against each
other.
P-EXTENSION REMOVAL
(REA 9000R)
1. Remove transformer connecting screw and
remove plug from transformer.
2. Remove two (2) P-extension screws from bot-
tom mounting plate. Pull P-extension away.
3. Remove two (2) nylon screws from body.
4. Gently pull P-extension from body locating
the two (2) spacers.
P-EXTENSION
REPLACEMENT
(REA 9000R)
1. Locate two (2) spacers in the counter bores of
the body.
2. Locate the two (2) spacers in counter bores of
the P-extension.
3. Secure the two (2) nylon screws in the body.
4. Locate the P-extension into the bottom plate
and fasten using two (2) screws.
5. Reinstall P-extension plug in transformer
using screw.
Ransburg
REA Automatic Applicators - Maintenance
36