CR00014304

LLDP

3

The help displayed for the LLDP port parameter (in such commands as
show lldp port=?) incorrectly indicated that the port parameter is a
“string 1 to 255 characters long”. The port parameter is instead an
Ethernet switch port number or a range of numbers.

This issue has been resolved. The help is now correct.

Y

-

Y

Y

Y

Y

Y

Y

Y

Y

Y

CR00014330

Ping

3

The maximum value for the delay parameter of the ping command was
too long.

This issue has been resolved by changing the range for the delay from
0-4294967295 to 0-604800. This new maximum is the number of seconds
in one week.

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

CR00014879

Switching,

RSTP, SNMP

3

Previously, an incorrect value was returned for the port number when
responding to an SNMP Request for MIB object dot1dSTPRootPort.

This issue has been resolved.

-

-

-

Y

Y

Y

Y

Y

Y

Y

Y

CR00015466

Core, Install,

PoE

3

The output of the show cpu command on the AT-8624POE switch showed
relatively high CPU usage when the device was idle.

This issue has been resolved.

-

-

-

-

-

-

Y

-

-

-

-

CR00016183

File

3

If a user attempted to delete a locked file, such as the currently-installed
GUI resource file, the router or switch displayed both an operation error
message and an operation successful message.

This issue has been resolved by removing the incorrect operation successful
message.

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

CR00016429

OSPF

3

Previously, OSPF logged the same message for two separate errors. These
errors were when OSPF rejected a database description message because:

the neighbour was in a state of “down” or “attempt”, or

the MTU received from the neighbour was larger than the receiving
system could handle.

This issue has been resolved. Separate error log messages are now
generated for these two errors.

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y