Section 5: Service and Maintenance

08/12

41

51300 Rev. 1

5.2.2. Solutions

For all errors not listed or for help, please call your local Fairbanks Service Representative.

SYMPTOM

CAUSE

SOLUTION

“UL1”

or

“UL2”

• Below

ZERO

• Bind

Check for platform bind.

Check that the “S” hook is attached.

Check that the hook is under the lever’s end at

the bottom of the scale.

Check for proper platform assembly.

Possible damaged load cell.

Call for service.

“OL1”

or

“OL2”

• Over Capacity
• Bind
• Possible damaged

load cell.

• Possible A/D failure.

Check platform to be empty, then press

ZERO

.

Check for platform bind.

Call for service.

Does not return to

“0.0”

• Bind

Check for platform bind.

Check that the “S” hook is attached.

Check that the hook is under the lever’s end at

the bottom of the scale.

Check for proper platform assembly.

“Error3”

• Bind
• Possible damaged

load cell.

• Possible A/D failure.

Check for platform bind.

Check that the “S” hook is attached.

Check that the hook is under the lever’s end at

the bottom of the scale.

Check for proper platform assembly.

Call for service.

Blank display

• Battery pack

discharged.

• No power at outlet
• Batteries dead
• Faulty instrument

Replace or Recharge the battery pack.

Check AC outlet; check circuit box.

Call for service.

“LoBAtt”

• Batteries low

Recharge the battery pack.