beautypg.com

Setup piece weight by sampling (place item) – Fairbanks 1129 SERIES Dual Platform Counting Scale User Manual

Page 26

background image

Section 4: User Operations

08/12

26

51300 Rev. 1

4.5.3. Setup Piece Weight by Sampling (Place Item)

1. Set the Piece Weight on

ZERO

.

– The scale will calculate the Piece Weight Value by what is added and Piece

Count Number, as described below.

2. Press the key.

– The second row of LCD displays .

– The third row displays a default value of 100.

3. Enter the new sampling quantity using the keypad.

4. Place the items to be weighed onto the scale pan.

– Wait five (5) seconds for the weight to stabilize.

– The Piece Weight calculates automatically, or press the key

to calculate immediately.

5. Press to clear the Piece Weight.

EXAMPLE

1. Press .

2. Press to set this at the number of Pieces.

– This displays on the third line.

3. Place a one pound (1 lb) test weight on the scale weighing pan.

– Wait five (5) seconds for the weight to stabilize.

– The Piece Weight displays as

0.2,

and the Piece Count displays as five

(

5

).

NOTE:

If weighing is performed on an external scale, after pressing , the

sampling job continues on main scale automatically when

AUTO SWITCH

is configured in the Scale Counting Parameter Setting.