Setup piece weight by sampling (remove item) – Fairbanks 1129 SERIES Dual Platform Counting Scale User Manual
Page 27

Section 4: User Operations
08/12
27
51300 Rev. 1
4.5.4. Setup Piece Weight By Sampling (Remove Item)
1. Set the Piece Weight on
ZERO
.
2. Place a item on the weighing pan.
– The scale will calculate the Piece Weight Value by the change in weight.
3. Press .
– The second row of LCD displays
.
– The third row of LCD displays the default value as 100.
4. Press the numeric keys to enter the new sampling quantity.
5. Remove the items to obtain the desired piece counts value from the weighing
pan.
– The piece weight will be calculated automatically.
6. Press to clear the Piece Weight amount.
EXAMPLE
1. Place a five pound (5 lb) test weight on the scale weighing pan.
2. Press .
3. Press to set this as the number of pieces to be removed.
– It displays on the third line.
4. Remove the one pound (1 lb.) item from scale weighing pan.
– Wait for five (5) seconds after the weight is stable.
– The piece weight displays 0.2, and piece count displays 20.
NOTE:
If weighing is performed on an external scale, after pressing , the
sampling job continues on main scale automatically when
AUTO SWITCH
is configured in the Scale Counting Parameter Setting.
.