Recall, continued – Fairbanks 1129 SERIES Dual Platform Counting Scale User Manual
Page 35
![background image](/manuals/347068/35/background.png)
Section 4: User Operations
08/12
35
51300 Rev. 1
4.7.2. Recall, Continued
RECORD VIEW MODE
1. Enter the
Total Mode
.
2. Press to enter record view mode.
3. Toggle through each of the stored accumulation records in memory by pressing
the .
– If current record is the last record, it will return to total mode.
– The number shown above the “ACC” indicates the number of current record.
Weight, Piece Weight and Piece is the data of current record.
4. Press to return to the Weight Mode.
5. Press to clear current record.
EXAMPLE
1. Clear scale weighing pan. Make sure the weight is 0. If weight is not 0, use zero
key to reset.
2. Press the + keys to set Piece Weight as 0.5 pounds.
3. Put a one pound (1 lb.) item on scale weighing pan
– Wait five (5) seconds for the scale to stabilize.
4. Press .
– After on beep sound,
lights up.
5. Remove the item from the scale weighing pan. Make sure the weight is 0 again.
6. Press + key to set Piece Weight as 0.1 pounds.
7. Put a two pound (2 lbs.) item on scale weighing pan
– Wait five (5) seconds for the scale to stabilize..
8. Press .
– After on beep sound,
lights up.
9. Press to enter the Total Mode again.
10. Press again to access the record view mode.