4.7.2. Recall

TOTAL MODE

1. In weighing mode, press and the Weight column will be cleared.

– The Piece Weight column displays

.

2. The PCS column shows the total piece count in memory.

– The Weight column shows the accumulated weight.

3. The number above “ACC” indicator is the record size.

4. Press to exit without clearing the data.

5. Press to clear the data and exit.

EXAMPLE

1. Clear scale weighing pan. Make sure the weight is 0. If weight is not 0, use zero

key to reset.

2. Press the + keys to set Piece Weight as 0.5 pounds.

3. Put a one pound (1 lb.) item on scale weighing pan

– Wait five (5) seconds for the scale to stabilize.

4. Press .

– After on beep sound,

lights up.

5. Press to into total mode. The Weight shows 1 pound.

– The Piece shows 2.

6. Press to back to normal mode. The ACC data still in flash, and

still

lights up.

7. Press key to into total mode again.

8. Press to clear all flash and back to normal mode.

ACC Data clears, and

is gone.