Plc1 bank data – FEC AFC1200 User Manual

Page 21

background image

)(& ,QF

SEQ OUT 4

DATA 7

SEQ OUT 3

DATA 6

SEQ OUT 2

DATA 5

These four outputs are available to indicate
that the fastening sequence has reached a
step that has an out port [OUT] command
inserted. Used to provide sequence operation
status out to the PLC.

SEQ OUT 1

DATA 4

SPARE

SPARE

DATA 3

SPARE

SPARE

DATA 2

Reserved for future use.

HD FULL WRN

DATA 1

Output when System is in Program mode.

PROGRAM

DATA 0

ON

OFF

2

SEQUENCE 2

DATA 7

SEQUENCE 1

DATA 6

Output confirmation of SEQUENCE SELECT
0~2 (Pins 9~11) input selections.

SEQUENCE 0

DATA 5

Output after a START signal is received, and
active until the fastening cycle is complete and
the READY signal is output. System will also
output this signal when performing a Zero, Cal,
or Offset Check.

BUSY

DATA 4

Output when the System is in READY
condition. Indicates the System is ready to
operate, and inputs are enabled. This signal is
inactive (off) when the BUSY output is active
(on).

READY

DATA 3

Output when a System Abnormal occurs.
Indicates that the System has detected a fault,
and will not continue operation. The Abnormal
code/description is displayed on the front of the
Axis Unit and/or on the System CRT. The
Abnormal condition must be corrected before
normal operation will resume. Refer to
Chapter 9 Troubleshooting.

ABNORMAL

DATA 2

Output when the fastening result is an
ACCEPT. Indicates all spindles are within
fastening limits. This output remains active
until the START signal or RESET signal is
input.

ACCEPT

DATA 1

Output when the fastening result is a REJECT.
Indicates one (1) or more spindles has
exceeded fastening limits. This output remains
active until the START signal or RESET signal
is input.

REJECT

DATA 0

OFF

OFF

1

DESCRIPTION

NAME OF

SIGNAL

BANK DATA

PINS 23~30

0

PIN 21

1

PIN 22

BANK

#

PLC1 BANK DATA

BANK

SELECT

INPUT

Chapter 4: System Setup and Wiring

Page 4-21