beautypg.com

FEC AFC1200 User Manual

Page 18

background image

)(& ,QF

Used only if JP2-1 jumper is in place on Multi2 PCB, these
Commons are for optional user-supplied +12~24 VDC power supply
for PLC input. If internal +5 volt supply (JP2-2 jumper) is used, then
this connection is not required. Refer to Figure 4-7-6 PLC Wiring
Sample.

IN COM
IN COM

15
16

Bank Select Output Signals (Normally Open)
These outputs echo Bank Select 0 & 1 inputs (PLC1 Pins 21 & 22).

BANK SELECT OUT 0
BANK SELECT OUT 1

13
14

Spare inputs.

SPARE 1
SPARE 2
SPARE 3
SPARE 4

9
10
11
12

Bank Data Output Signals (Normally Open)
These output signals designate various fastening conditions and
results as determined by Bank Select 0 & 1 (PLC1 Pin 21 & 22)
inputs. Refer to 4.7.3 Bank Select Table for output data
descriptions.

BANK DATA 8
BANK DATA 9
BANK DATA 10
BANK DATA 11
BANK DATA 12
BANK DATA 13
BANK DATA 14
BANK DATA 15

1
2
3
4
5
6
7
8

DESCRIPTION

SIGNAL NAME

PIN #

PLC2 (EXTENDED PLC) I/O SIGNALS

Common from power supply (0 VDC).

0 VDC COM
0 VDC COM

33
34

Common for PLC Output (0 VDC).

OUT COM
OUT COM

31
32

Bank Data Output Signals (Normally Open)
These output signals designate various fastening conditions and
results as determined by Bank Select 0 & 1 (Pins 21 & 22) inputs.
Refer to 4.7.3 Bank Select Table for output data descriptions.

BANK DATA 0
BANK DATA 1
BANK DATA 2
BANK DATA 3
BANK DATA 4
BANK DATA 5
BANK DATA 6
BANK DATA 7

23
24
25
26
27
28
29
30

DESCRIPTION

SIGNAL NAME

PIN #

PLC1 OUTPUT SIGNALS

Bank Select Input Signals (Normally Open)
These two (2) inputs form a binary code that is used to define the
function/definition of outputs Bank Data 0~7 (PLC1 Pins 23~30) and
Bank Data 8~15 (PLC2 Pins 1~8). This allows up to 64 different
output definitions with only 16 discrete outputs (four Banks, 16
available outputs per Bank). Refer to 4.7.3 Bank Select Table.

BANK SELECT 0
BANK SELECT 1

21
22

Bypass Head Input (Normally Open)
These four inputs are available to bypass the heads (groups of
spindles) designated A, B, C or D (on the Machine Configuration
screen).

BYPASS HEAD A
BYPASS HEAD B
BYPASS HEAD C
BYPASS HEAD D

17
18
19
20

External Sequence Input (Normally Open)
Four input signals are available to use as external sequence inputs
to the fastening sequence. When a [WAT] wait command is
programmed as a step in the fastening sequence, the sequence will
stop until this external input is active.

INPUT PORT 1
INPUT PORT 2
INPUT PORT 3
INPUT PORT 4

13
14
15
16

DESCRIPTION

SIGNAL NAME

PIN #

PLC1 INPUT SIGNALS

Chapter 4: System Setup and Wiring

Page 4-18