FEC AFC1200 User Manual
Page 16
![background image](/manuals/346011/16/background.png)
)(& ,QF
Reset Input (Normally Open)
When active (on), this signal will clear all fastening data, discrete
outputs, and communication buffers. A Zero Check of all torque
transducers will be completed. During the Zero Check, the CHECK
lamp will illuminate, the READY signal will deactivate, and the
ACCEPT or REJECT lamp will light to indicate the result of the Zero
Check. If the System has been disabled by an Abnormal output, the
System will not return to normal operation until the Abnormal
condition has been corrected, and this signal has been input for
200~500 milliseconds. Do not input this signal between cycles, due
to the potential for data loss.
RESET
2
Emergency Stop Input (Normally Closed)
This signal must be active (on) for Controller operation. When this
signal is inactive (off), all Controller operation ceases, all spindles in
motion will stop, and all communication ports, inputs, and outputs will
be disabled.
STOP
1
DESCRIPTION
SIGNAL NAME
PIN #
PLC1 INPUT SIGNALS
Chapter 4: System Setup and Wiring
Page 4-16