PASCO ES-9060 Charge, Equipotential and Field Mapper User Manual

Page 16

background image

®

Model No. ES-9060

Charge, Equipotential, and Field Mapper

15

source is a straight line at the left, the sink is a straight line at the right.
The tear-drop shaped section cut out of the middle is some obstruction.
The field lines are the corresponding streamlines.

Procedure:

To use the Field Mapper to examine field flows, follow these steps.

1. Make sure that the fluid is incompressible and the flow is not rotational

and steady.

2. Draw the electrodes on the conductive paper in the same shape and

position as the sources and the sinks in the flow.

3. Cut out the sections of the conductive paper in the same shape and

position as the obstructions in the fluid.

4. Connect a battery between the sources and the sinks. All sources

should be connected to the same side of the battery. All sinks
should be connected to the opposite side.

5. Plot the equipotentials and draw lines perpendicular to these. You

can also pick any point and determine the direction of the
maximum field gradient. This is the direction of the streamlines at
that point.