1. Resin supply should be thoroughly mixed before being used. Central
bulk resin systems should have filter between supply and pump to prevent
clogging. Place resin supply adjacent to unit and insert resin wand into
resin container.
2. Open resin pump air valve.
3. Slowly turn pump operating air regulator (clockwise)until resin pump
is stroking steady, even strokes (approximately 10 to 20 psi).
4. Shut off air to resin pump by:
-turning regulator to zero or
-turning off pump air control valve
5. Close gun and flush into suitable
waste container.
6. Position resin drain hose (located under
resin filter), into resin drum or suitable
waste container. Open resin drain ball valve.
7. Insert charging hose quick disconnect to
top of resin accumulator and hold down
for 10 seconds. Then remove. (See Fig. 3B)
Priming the Resin Pump
Fig. 3B
PRIMING THE RESIN PUMP
5
Although we recommend you pressurize the chamber,
in some cases there may not be a need to charge
depending upon material, pump pressure and tip size.
NOTE
As resin enters the pump, you may have to increase psi
slightly in order to maintain even pump strokes.
Observe gun to make sure resin pours from the gun
block evenly with no air in the stream.