beautypg.com

Magnum Venus Plastech HIS SUPERCHARGED User Manual

Page 7

background image

SUPERCHARGED H.I.S.™

START-UP PROCEDURE

10. Slowly open flush air control valve located on manifold.

11. Remove nozzle assembly, and turbulent mixer from gun. (See Fig. 2F)

12. Push flush button (located on the side of the gun block, see Fig. 2G)
untilsolvent exits the gun block. Release button and check entire flush
system for leaks.

13. Set the gun regulator (located on the manifold) between 90 and 100
psi.

14. Position gun over suitable container and pull trigger. Be sure gun
remains open during priming procedure.

Fig. 2F

Fig. 2G

3

Release pressure from flush system before any
corrective action takes place. To relieve pressure, turn
flush air control valve to off position and lift up on lever or
ring of relief valve located on top of flush tank.

NOTE