beautypg.com

Magnum Venus Plastech HIS SUPERCHARGED User Manual

Page 11

background image

SUPERCHARGED H.I.S.™

PRIMING THE RESIN PUMP

10. Install turbulent mixer and nozzle assembly onto the gun block. Align
nozzle (spray or flowchop) in horizontal position. NOTE: refer to the
nozzle chart in the H.I.S. System Instruction Manual for appropriate nozzle
selection.

11. Slowly open resin pump air valve and slowly turn pump operating
pressure regulator to recommended setting (40 to 50) psi. Resin and
catalyst pump will stroke until fluid line pressure is reached. Check all
fittings for leaks.

12. Using priming knob, hand prime the catalyst pump until fluid pressure
resistance is felt in the stroke.

13. Connect catalyst pump to slave arm using the quick pins to desired
setting.

Always remember to turn off regulator and slowly open gun
trigger to bleed system before any disassembly or repair
takes place.

NOTE

7

To avoid damage to the catalyst pump, always connect
quick pins to the same percentage holes on the upper and
lower slave arm.

CAUTION