beautypg.com

Magnum Venus Plastech HIS SUPERCHARGED User Manual

Page 5

background image

SUPERCHARGED H.I.S.™

1. Check all fittings for proper connection.

2. Fill resin pump power head oiler to designated mark on oiler using light

weight oil provided with the unit or available from MVP when supply is
depleted. (See Fig. 2A)

3. Fill resin pump cavity (center section) approximately 1/3 full using the oil

provided, or a standard 30 weight motor oil. (See Fig. 2B)

4. Turn all regulators counter-clockwise so gauges will read zero when air

is connected to system. (See Fig. 2C)

5. Pull top quick pin from catalyst pump slave arm. (See Fig. 2D)

Start-up procedure

The following steps should be followed when the unit is
new, has been recently repaired or has no material in the
system.

NOTE

Fig. 2A

Fig. 2B

1

Chapter

2

22