beautypg.com

Stop – Magnum Venus Plastech HIS SUPERCHARGED User Manual

Page 17

background image

SUPERCHARGED H.I.S.™

Fig. 6A

Fig. 6B

8. Clean filter tank, filter screen and filter core in solvent.

9. Slowly unscrew accumulator.

10. Clean the accumulator in solvent.

The resin filter will need cleaning on a regular basis
depending on the material used. Filter screen will show
the degree of contaminates to judge cleaning intervals. It
is not necessary to completely flush resin system to clean
filter, but follow proper fluid pressure bleeding
procedure before removing the filter.

NOTE

REMOVING MATERIALS FROM THE SYSTEM

7. Place suitable container under the resin filter and slowly unscrew the filter
tank from the filter body.

13

Always wear safety glasses and protective clothing.

CAUTION

Stop if accumulator is hard to unscrew by hand. This
may indicate than an air charge still exists in the
accumulator and cannot be discharged from the check
valve.

If this happens, continue to unscrew very slowly,
stopping once every revolution to allow pressure to
escape through the relief cut into the threads of the
accumulator mounting nipple.

STOP

The accumulator should be cleaned weekly to prevent resin
gelation.

CAUTION