PRIMING THE RESIN PUMP

a. Be sure resin drain ball valve is open. (See Fig. 3C)

b. Remove air charge from resin accumulator by inserting 1/8” rod
(provided), into fitting on top of accumulator while pressing the
check valve. (See Fig. 3D & 3E)

c. Slowly unscrew accumulator from the accumulator adaptor.

d. Clean accumulator and poly ball with a clean rag or solvent (if needed).

e. Reassamble.

f. Repeat steps 6 & 7.

Fig. 3C

Fig. 3D

Fig. 2E

8. While holding charging hose on resin accumulator fitting, listen for air
exhausting from the resin dump hose. If no air is exhausting, proceed to
step 9. If air is heard exhausting, the accumulator ball is not seating
properly and the following procedure must be performed:

9. Close the resin drain ball valve under the resin filter. (See Fig. 3C)

6

Quick disconnect will not lock onto accumulator fitting.
This is intentional as it is not recommended to leave the
charging hose connected.

NOTE

Stop if accumulator is hard to unscrew by hand. This
may indicate that an air charge still exists in the
accumulator and cannot be discharged from the check
valve.

If this happens, continue to unscrew very slowly,
stopping once every revolution to allow pressure to
escape through the grooves into the threads of the
accumulator mounting nipple.

STOP