Catalyst Overpressure circuit is engaged (check indicator on panel)
Check for blockage in catalyst delivery lines.
Check FC #04 for proper adjustment.
Check for air leaks on Catalyst Overpressure valve and connection 1B-7(21).
Internal Catalyst Overpressure circuit check
Check (21) for leaks
Check V03 output (49) for signal. Should not be on.
Predetermined counter not counting or skipping counts
Will not count in recirculation mode
FC#03 not adjusted properly
Adjust FC#03 for proper flow
.
Faulty signals from powerhead shift block
Repair or replace powerhead shift block.
Faulty RGA V03 valve or OR09 shuttle
Check (60) for signal. Should go on/off with pulses from powerhead.
Faulty counter
Check (60) for signal. Should go on/off with pulses from powerhead.
Cat op circuit does not stop pump
FC#04 not adjusted properly.
Adjust flow control
Remove (21) from Catalyst Overpressure valve, start pump, slowly turn in FC#04 until pump stops.
MPG will not stop pump on overpressure
Reduce MPG pressure from panel.
FC#04 not adjusted properly
.
Adjust flow control
Remove (26) from MPG valve, start pump, slowly turn in FC#06 until pump stops.
Gel alarm time incorrect
FC#03 not adjusted properly.
Adjust flow control until gel alarm is set correctly.
Gel alarm not working
FC#03 not adjusted properly.
Adjust flow control until gel alarm is set correctly.
Check RGA V02 (51) for signal. Should be off/pulsing when pumping. On when not pumping.
Check RGA V02 output (52) for signal. Should be off/pulsing when pumping. On when not pumping.
Flush dwell time incorrect
FC#05 not adjusted properly
.
Adjust flow control until flush dwell is set correctly.
Flush not working
FC#05 not adjusted properly.
Adjust flow control until flush dwell is set correctly.