CHAPTER 4-Overview of Controls

Overview of controls

The Innovator control panel is shown in figure 4.10. Controls have been grouped based upon function, to make the
system as user friendly as possible.

A brief overview of controls is as follows:


Emergency Stop

Push button

Press this button in the event of an emergency to place the system in a
safe state. Twist and pull to release and allow machine operation.

Pump pressure

Pressure gauge

This is the air pressure being supplied to the pump.

Regulator

Adjust this to control the air pressure being supplied to the pump and set

the pump speed.

Flush/Alarms

CAT/OP

Indicator will turn red if overpressure state exists.

RGA ALARM

Indicator will turn red if gel alarm timer has expired.

Pushbutton

Press this button to operate the flush cycle.

Mold Pressure Guard

Preset level gauge Control signal air pressure being supplied to Mold Pressure Guard

(MPG) control.

Regulator

Use this to adjust the MPG control signal air pressure.


Start/Stop Controls

Inject

Press to start the machine in inject mode.

Recirculate

Press to start the machine in recirculation mode.

Stop

Press to stop the machine in injection, recirculation or flush modes.



Stroke Counter

Set a predetermined stroke count for the machine to stop at.