INSTALATION/OPERATIONS MANUAL

INNOVATOR II

MAGNUM VENUS PLASTECH

REV 1.40

MAY 2012

PAGE 31

RGA V01

RESIN GEL ALARM VALVE

In the on position, supplies RGA circuit.

In the off position, removes supply from RGA circuit.

Triggered by INJECT PB 01 or REMOTE INJECTION SEQUENCE START VALVE (V01)

RGA V02

TIMER VALVE

In the on position, removes supply the RGA circuit.

In the off position, supplies the RGA circuit.

Triggered by RESIN GEL ALARM VALVE (RGA V01)

RGA V03

COUNTER CIRCUIT VALVE

In the on position, supplies the RGA circuit and counter circuit signal.

In the off position, removes supply to the RGA circuit and counter circuit signal.

Triggered by powerhead pulse signals.



S01

START UP SAFETY VALVE

In the on position, initiates the stop circuit and resets all valves.

Triggered by, main air pressure going from off to on.

S02

MPG LOW PRESSURE RELAY VALVE

In the on position, supplies signals to MPG GUN OVERIDE (V14) and MPG PUMP OVERIDE (V15).

In the off position removes signals from MPG GUN OVERIDE (V14) and MPG PUMP OVERIDE (V15).

Triggered by venting of the MPG block on the gun.

S03

CE NORM GUARD INTERLOCK VALVE

In the off position, supplies signal to stop circuit.

Triggered by opening the CE NORM guard.

S04

CATAYLST OVER PRESSURE VALVE

In the off position, supplies signal to stop circuit.

Triggered by venting of the Catalyst Overpressure block on the gun.