RESIN GEL ALARM VALVE
In the on position, supplies RGA circuit.
In the off position, removes supply from RGA circuit.
Triggered by INJECT PB 01 or REMOTE INJECTION SEQUENCE START VALVE (V01)
RGA V02
TIMER VALVE
In the on position, removes supply the RGA circuit.
In the off position, supplies the RGA circuit.
Triggered by RESIN GEL ALARM VALVE (RGA V01)
RGA V03
COUNTER CIRCUIT VALVE
In the on position, supplies the RGA circuit and counter circuit signal.
In the off position, removes supply to the RGA circuit and counter circuit signal.
Triggered by powerhead pulse signals.
S01
START UP SAFETY VALVE
In the on position, initiates the stop circuit and resets all valves.
Triggered by, main air pressure going from off to on.
S02
MPG LOW PRESSURE RELAY VALVE
In the on position, supplies signals to MPG GUN OVERIDE (V14) and MPG PUMP OVERIDE (V15).
In the off position removes signals from MPG GUN OVERIDE (V14) and MPG PUMP OVERIDE (V15).
Triggered by venting of the MPG block on the gun.
S03
CE NORM GUARD INTERLOCK VALVE
In the off position, supplies signal to stop circuit.
Triggered by opening the CE NORM guard.
S04
CATAYLST OVER PRESSURE VALVE
In the off position, supplies signal to stop circuit.
Triggered by venting of the Catalyst Overpressure block on the gun.