Internal push buttons and valve operations
PB01 INJECT PUSHBUTTON
Pilots RESIN GEL ALARM VALVE (RGA V01) INJECTION CYLCE START VALVE (V02) and disarms the flush cycle.
Must have a signal from AN1 to work.
PB02 REMOTE INJECT PUSHBUTTON
Pilots REMOTE INJECTION VALVE (V01).
Must have a signal from AN1 to work.
PB03 REMOTE STOP PUSHBUTTON
Pilots FLUSH CYCLE SIGNALS VALVE (V10), FLUSH INTERLOCK VALVE (V05) on and INJECTION CYCLE START VAVLE (V02) off.
Stops all functions of the Innovator and arms the flush cycle.
PB04 RGA RESET PUSHBUTTON
Pilots the RESIN GEL ALARM VALVE (RGA V01) valve off. This pushbutton is inside the box and accessible thru the side via small
probe.
PB05
PRIME PUSHBUTTON
Pilots INJECTION GUN VALVE (V06) to allow bypass of PPVS and MPG sensors to allow the Injection gun to dispense material.
Must have a signal from AN1 to work
PB06 STOP PUSHBUTTON
Pilots FLUSH CYCLE SIGNALS VALVE (V10), FLUSH INTERLOCK VALVE (V05) on and INJECTION CYCLE START VAVLE (V02) off.
Stops all functions of the Innovator and arms the flush cycle.
PB07 E STOP
Pilots FLUSH CYCLE SIGNALS VALVE (V10), FLUSH INTERLOCK VALVE (V05) on and INJECTION CYCLE START VAVLE (V02) off.
Stops all functions of the Innovator and arms the flush cycle
This is a maintained button, must be reset to allow machine to work.
PB08 FLUSH PUSHBUTTON
Pilots the RESIN GEL ALARM (RGA V01) valve off and pilots, FLUSH CYCLES SIGNAL VALVE on (V10)
Supplied from FLUSH INTERLOCK VALVE (V05).
PB09 RECIRCULATION PUSHBUTTON
Pilots RECIRCULATION GUN VAVLE (V07)
Supplied from RECIRCULATION INTERLOCK VALVE (V04)
V01
REMOTE INJECTION SEQUENCE START VALVE
In the on position, pilots the INJECTION GUN VALVE (V02) and RESIN GEL ALARM VALVE (RGA V01). Starts the injection
sequence
In the off position, pilots the FLUSH INTERLOCK VALVE (V05), allowing flush sequence to activate.
Triggered by REMOTE INJECT (PB02).
V02
INJECTION SEQUENCE START VALVE
In the on position, pilots the INJECTION GUN VALVE (V06), supplies TAS (RTM ONLY) panel plug and the COUNTER CIRCUIT
VALVE (RGA V03) allowing the injection sequence to start.
In the off position, pilots the FLUSH INTERLOCK VALVE (V05), allowing flush sequence to activate.
Triggered by INJECT (PB01) or REMOTE INJECT (PB02).