Reassembling the Meter
Tools:
Cover socket or open end/box end wrench
Spare displacement rotor gear
Rotor gear wrench or socket
Bearing Plate wrench or socket
NOTE: See Page 25 for Torque Chart and Wrench and
Socket Size Chart.
NOTE: The principles of meter disassembly and
reassembly are the same for all the Liquid Controls
Positive Displacement meters. Although your meter may
look slightly different than those pictured, the steps are
the same except as noted.
1.
Rotor gears are on the front bearing plate. Install the
non-rotor gear bearing plate using the bearing plate
screws and wrench.
2.
Insert the non-tapered ends of the three rotors into
the housing from the opposite side. Place each rotor
into its respective bore in the installed bearing plate.
3.
Place the remaining bearing plate over the three
tapered rotor ends and fasten it with the bearing plate
screws. Use the bearing plate wrench.
- Gear Plate Selection Guide (24 pages)
- MS Meters (40 pages)
- M-MA Meters (28 pages)
- HMS3700 & HMS3770 Insertion Sensors LC Mag Insertion (8 pages)
- HMS501, HMS600, HMS1000, HMS2400, HMS2500, and HMS5000 LC Mag IOM (8 pages)
- CIM100 (16 pages)
- Rate of Flow (4 pages)
- HML4-F1 - LCMag (40 pages)
- LCRII Install E3650-E3651 Series (40 pages)
- LCR-II Setup & Operation (60 pages)
- LCRII Menu Map (2 pages)
- LCR-II - Quick Reference (2 pages)
- LCR Install (24 pages)
- LCR Setup & Operation (60 pages)
- LCR 600 Install (36 pages)
- LCR600 Wiring Schematic (1 page)
- LCR 600 Setup & Op (68 pages)
- LCR 600 - Quick Reference (2 pages)
- FlightConnect 600 (52 pages)
- FlightConnect 600 QR (2 pages)
- LCR-II Installation E3655-E3656 (36 pages)
- LCRII E3651-E3656 Wiring Schematic (1 page)
- DMS Installation (20 pages)
- DMS Setup (84 pages)
- DMS Delivery (52 pages)
- DMS i1000 Quick Reference - DMS Delivery (2 pages)
- DMS Office (52 pages)
- DMS i1000 EZConnect Operators (36 pages)
- DMS i1000 Quick Reference - EZConnect (2 pages)
- EZConnect Office (44 pages)
- FlightConnect Office (36 pages)
- FlightConnect Setup Guide (8 pages)
- DB Manager (20 pages)
- POD (16 pages)
- Dual Meter Multiplexer (8 pages)
- Differential Pressure Transducer (12 pages)
- XL LED Display E1615_E1616_E1617_E1618 (20 pages)
- SCAMP (20 pages)
- WinHost Operation (44 pages)
- SP714-S2i (12 pages)
- HML110 IOM (31 pages)
- HML210 IOM - LCMag (44 pages)
- Sponsler T675 - Cryogenic System Register (54 pages)
- Sponsler IT400 Electronic Register (40 pages)