1 1 Relay1 Off when Al1 active, Relay2 Off when Al2 active

0B (U)

Alarm Confg2

Bit 7 6 5 4 3 2 1 0 Alarm Trigger Delay

60 Hz

50Hz

0 0 0

0.018s

0.021s

0 0 1

0.035

0.043

0 1 0

0.07

0.085

0 1 1

0.14

0.17

1 0 0

0.28

0.34

1 0 1

0.56

0.68

1 1 0

1.13

1.36

1 1 1

2.27

2.72

Alarm Comparison

0 0

Al1 Net, Al2 Net

0 1

Al1 Gross, Al2 Net

1 0

Al1 Net, Al2 Gross

1 1

Al1 Gross, Al2 Gross

0D (U)

Alarm Cnfg 4

Same as for DPM, page 35

0C (U)

Alarm Cnfg 3

Same as for DPM, page 35

BF (L)

Analog Output
Setup

Bit 7 6 5 4 3 2 1 0

0 0 Filtered Net

0 1 Filtered Gross

1 0 Unfiltered Net

1 1 Unfiltered Gross

0 0

Current Output (0-20 mA)

0 1

Voltage Output (0-10V)

1 0

Current Output (4-20 mA)

1 1

Voltage Output (-10 to +10V)

31 (L)

Serial Cnfg1

Bit 7 6 5 4 3 2 1 0 Continuous Output Data Rate

60 Hz

50 Hz

0 0 0 0

0.017s

0.020s

0 0 0 1

0.28

0.34

0 0 1 0

0.57

0.68

0 0 1 1

1.1

1.4

0 1 0 0

2.3

2.7

0 1 0 1

4.5

5.4

0 1 1 0

9.1

10.9

0 1 1 1

18.1

21.8

1 0 0 0

36.3

43.5

1 0 0 1

1:13

1:27