Laurel Electronics Custom ASCII Protocol For Laureate Series 2 Digital Panel Meters, Counters, Timers & L-Series Transmitters User Manual
Page 50
50
0 1 1 1 Moving Average 2.27 2.72
1 0 0 0 Moving Average 4.53 5.44
1 0 0 1 Moving Average 9.06 10.9
1 0 1 0 Moving Average 18.1 21.8
1 0 1 1 Moving Average 36.2 43.5
1 1 0 0 Moving Average 72.5 87.0
1 1 0 1 Moving Average 145
174
1 1 1 0 Moving Average 290
348
1 1 1 1 Unfiltered (Used with Hold)
0
Low adaptive threshold
1
High adaptive threshold
0
Display value of 16-reading batch
1
Display value of filtered signal
0
Take peak of unfiltered signal
1
Take peak of filtered signal
0
Alarm from unfiltered signal
1
Alarm from filtered signal
35 (L)
Decimal Point
Bit 7 6 5 4 3 2 1 0 Meter Display
0 0 1 XXXXX. (dec point not displayed)
0 1 0 XXXX.X
0 1 1 XXX.XX
1 0 0 XX.XXX
1 0 1 X.XXXX
1 1 0 .XXXXX
0A (U)
Alarm Confg1
Bit 7 6 5 4 3 2 1 0
0 0 0 0 Al1 Hi active, Al2 Hi active
0 0 0 1 Al1 Lo active, Al2 Hi active
0 0 1 0 Al1 Disabled, Al2 Hi active
0 1 0 0 Al1 Hi active, Al2 Lo active
0 1 0 1 Al1 Lo active, Al2 Lo active
0 1 1 0 Al1 disabled, Al2 Lo active
1 0 0 0 Al1 Hi active, Al2 disabled
1 0 0 1 Al1 Lo active, Al2 disabled
1 0 1 0 Al1 disabled, Al2 disabled
0 0
Al1 & Al2 non-latching
0 1
Al1 latching, Al2 non-latching
1 0
Al1 non-latching, Al2 latching
1 1
Al1 & Al2 latching
0 0 Relay1 On when Al1 active, Relay2 On when Al2 active
0 1 Relay1 Off when Al1 active, Relay2 On when Al2 active
1 0 Relay1 On when Al1 active, Relay2 Off when Al2 active