Press Menu
Select Key

Press Digit Select
Key

Press Value Select
Key

00000U

RS485 half or full duplex

0

Full duplex

1

Half duplex

00000U

Special start & stop char.
(entered using Instrument
Setup Software)

0

*

Start, Stop characters

1

Special Start & Stop characters

00000U

RTS mode (for RS232)

0

Normal non-latching RTS

1

Single transmission, latching RTS

00000U

Termination characters

0

Only at end of all items

1

At end of each item

00000U

Data sent, digital panel meter
only

0

Reading

1

Peak

2

Valley

3

Reading + Peak

4

Reading + Valley

5

Reading + Peak + Valley

.

SEr 3

.

Serial Setup 3

00000U

Data sent, scale meter only

0

Net + Gross

1

Net only

2

Gross only

3

Peak only (Net or Gross)

4

Net + Gross + Peak

5

Valley only

__000U

Modbus ASCII gap timeout*

0

1 sec

2

5 sec

1

3 sec

3

10 sec

__000U

Serial protocol

0

Custom ASCII

1

Modbus RTU*

2

Modbus ASCII*

SEr 4

.

Serial Setup 4

__000U

Parity

0

None

1

Odd (Modbus only)*

2

Even (Modbus only)*

_

Addr

Modbus Address*

__000 __000 __000

Select digit to flash.

__158

Select

0

through

9

for flashing digit.

Address range is 1 to 247.

*

Modbus is not applicable to our weight meter.