Laurel Electronics Custom ASCII Protocol For Laureate Series 2 Digital Panel Meters, Counters, Timers & L-Series Transmitters User Manual
Page 45
45
0D U
Alarm Cnfg 4
Same as for DPM, page 35
0C U
Alarm Cnfg 3
Same as for DPM, page 35
0A U
Alarm Cnfg 1
Bit 7 6 5 4 3 2 1 0
0 0 0 0
Al1 Hi Active, Al2 Hi Active
0 0 0 1
Al1 Lo Active, Al2 Hi Active
0 0 1 0
Al1 Disabled, Al2 Hi Active
0 1 0 0
Al1 Hi Active, Al2 Lo Active
0 1 0 1
Al1 Lo Active, Al2 Lo Active
0 1 1 0
Al1 Disabled, Al2 Lo Active
1 0 0 0
Al1 Hi Active, Al2 Disabled
1 0 0 1
Al1 Lo Active, Al2 Disabled
1 0 1 0
Al1 Disabled, Al2 Disabled
0 0
Al1 Non-Latch, Al2 Non-Latch
0 1
Al1 Latch, Al2 Non-Latch
1 0
Al1 Non-Latch, Al2 Latch
1 1
Al1 Latch, Al2 Latch
0 0 Relay1 On when Al1 active, Relay2 On when Al2 active
0 1 Relay1 Off when Al1 active, Relay2 On when Al2 active
1 0 Relay1 On when Al1 active, Relay2 Off when Al2 active
1 1 Relay1 Off when Al1 active, Relay2 Off when Al2 active
11.2 COUNTER / TIMER 2-BYTE RAM DATA TABLE
Hex MS Hex LS
Name
Hex Range
Dec Range
40
3A
38
3F
39
37
Pulses
Timeout
Gatetime
0000 – EA5F
0000 – 4E1F
0000 – 4E1F
0 – 59999 Positive magnitude (Units = 1)
0 – 19999 Positive magnitude (Units = 0.01 sec)
0 – 19999 Positive magnitude (Units = 0.01 sec)
11.3 COUNTER / TIMER 3-BYTE RAM DATA TABLE
Hex MS Hex Mid
Hex LS
Name
Stored as
B0 (L)
AA (L)
9E (L)
AD (L)
A4 (L)
9B (L)
1B U
18 U
AF
A9
9D
AC
A3
9A
1A
17
AE
A8
9C
AB
A2
99
19
16
Deviation2 (values always+) (Hysteresis2)
Offset2
Setpoint2
Deviation1 (values always+) (Hysteresis1)
Offset1
Setpoint1
Deviation4
Deviation3
Values stored
as 3-byte 2’s
complement