0D U

Alarm Cnfg 4

Same as for DPM, page 35

0C U

Alarm Cnfg 3

Same as for DPM, page 35

0A U

Alarm Cnfg 1

Bit 7 6 5 4 3 2 1 0

0 0 0 0

Al1 Hi Active, Al2 Hi Active

0 0 0 1

Al1 Lo Active, Al2 Hi Active

0 0 1 0

Al1 Disabled, Al2 Hi Active

0 1 0 0

Al1 Hi Active, Al2 Lo Active

0 1 0 1

Al1 Lo Active, Al2 Lo Active

0 1 1 0

Al1 Disabled, Al2 Lo Active

1 0 0 0

Al1 Hi Active, Al2 Disabled

1 0 0 1

Al1 Lo Active, Al2 Disabled

1 0 1 0

Al1 Disabled, Al2 Disabled

0 0

Al1 Non-Latch, Al2 Non-Latch

0 1

Al1 Latch, Al2 Non-Latch

1 0

Al1 Non-Latch, Al2 Latch

1 1

Al1 Latch, Al2 Latch

0 0 Relay1 On when Al1 active, Relay2 On when Al2 active

0 1 Relay1 Off when Al1 active, Relay2 On when Al2 active

1 0 Relay1 On when Al1 active, Relay2 Off when Al2 active

1 1 Relay1 Off when Al1 active, Relay2 Off when Al2 active

11.2 COUNTER / TIMER 2-BYTE RAM DATA TABLE

Hex MS Hex LS

Name

Hex Range

Dec Range

40

3A

38

3F

39
37

Pulses
Timeout
Gatetime

0000 – EA5F
0000 – 4E1F
0000 – 4E1F

0 – 59999 Positive magnitude (Units = 1)
0 – 19999 Positive magnitude (Units = 0.01 sec)
0 – 19999 Positive magnitude (Units = 0.01 sec)

11.3 COUNTER / TIMER 3-BYTE RAM DATA TABLE

Hex MS Hex Mid

Hex LS

Name

Stored as

B0 (L)

AA (L)

9E (L)

AD (L)

A4 (L)
9B (L)

1B U

18 U

AF

A9

9D
AC

A3
9A
1A

17

AE
A8
9C

AB

A2

99
19
16

Deviation2 (values always+) (Hysteresis2)
Offset2
Setpoint2
Deviation1 (values always+) (Hysteresis1)
Offset1
Setpoint1
Deviation4
Deviation3

Values stored
as 3-byte 2’s