Laurel Electronics Custom ASCII Protocol For Laureate Series 2 Digital Panel Meters, Counters, Timers & L-Series Transmitters User Manual
Page 34
34
09 (U)
Setup1*
* Cannot be
written to RAM
Bit 7 6 5 4 3 2 1 0
0 0 4-1/2 digit display (0.1° temp.)
0 1 Remote display
1 0 4-1/2 digit count by 10 (0.01° t.)
1 1 3-1/2 digit display (1° temp.)
0D (U)
Alarm Confg4
Bit 7 6 5 4 3 2 1 0 Alarm Trigger Delay
60 Hz
50Hz
0 0 0
0.018 s 0.021 s
0 0 1
0.035
0.043
0 1 0
0.07
0.085
0 1 1
0.14
0.17
1 0 0
0.28
0.34
1 0 1
0.56
0.68
1 1 0
1.13
1.36
1 1 1
2.27
2.72
0 0 0
Al3 Band Dev, Al4 Band Dev
0 0 1
Al3 Hysteresis, Al4 Band Dev
0 1 0
Al3 Band Dev, Al4 Hysteresis
0 1 1
Al3 Hysteresis, Al4 Hysteresis
1 0 0
No deviation in menus or calc
0C (U)
Alarm Confg3
Bit 7 6 5 4 3 2 1 0
0 0 0 0 Al3 Hi active, Al4 Hi active
0 0 0 1 Al3 Lo active, Al4 Hi active
0 0 1 0 Al3 Disabled, Al4 Hi active
0 1 0 0 Al3 Hi active, Al4 Lo active
0 1 0 1 Al3 Lo active, Al4 Lo active
0 1 1 0 Al3 disabled, Al4 Lo active
1 0 0 0 Al3 Hi active, Al4 disabled
1 0 0 1 Al3 Lo active, Al4 disabled
1 0 1 0 Al3 disabled, Al4 disabled
0 0
Al3 non-latch, Al4 non-latch
0 1
Al3 latch, Al4 non-latch
1 0
Al3 non-latch, Al4 latch
1 1
Al3 latch, Al4 latch
0 0 Relay3 On when Al3 active, Relay4 On when Al4 active
0 1 Relay3 Off when Al3 active, Relay4 On when Al4 active
1 0 Relay3 On when Al3 active, Relay4 Off when Al4 active
1 1 Relay3 Off when Al3 active, Relay4 Off when Al4 active