beautypg.com

Laurel Electronics Custom ASCII Protocol For Laureate Series 2 Digital Panel Meters, Counters, Timers & L-Series Transmitters User Manual

Page 34

background image

34

09 (U)

Setup1*

* Cannot be
written to RAM

Bit 7 6 5 4 3 2 1 0

0 0 4-1/2 digit display (0.1° temp.)

0 1 Remote display

1 0 4-1/2 digit count by 10 (0.01° t.)

1 1 3-1/2 digit display (1° temp.)

0D (U)

Alarm Confg4

Bit 7 6 5 4 3 2 1 0 Alarm Trigger Delay

60 Hz

50Hz

0 0 0

0.018 s 0.021 s

0 0 1

0.035

0.043

0 1 0

0.07

0.085

0 1 1

0.14

0.17

1 0 0

0.28

0.34

1 0 1

0.56

0.68

1 1 0

1.13

1.36

1 1 1

2.27

2.72

0 0 0

Al3 Band Dev, Al4 Band Dev

0 0 1

Al3 Hysteresis, Al4 Band Dev

0 1 0

Al3 Band Dev, Al4 Hysteresis

0 1 1

Al3 Hysteresis, Al4 Hysteresis

1 0 0

No deviation in menus or calc

0C (U)

Alarm Confg3

Bit 7 6 5 4 3 2 1 0

0 0 0 0 Al3 Hi active, Al4 Hi active

0 0 0 1 Al3 Lo active, Al4 Hi active

0 0 1 0 Al3 Disabled, Al4 Hi active

0 1 0 0 Al3 Hi active, Al4 Lo active

0 1 0 1 Al3 Lo active, Al4 Lo active

0 1 1 0 Al3 disabled, Al4 Lo active

1 0 0 0 Al3 Hi active, Al4 disabled

1 0 0 1 Al3 Lo active, Al4 disabled

1 0 1 0 Al3 disabled, Al4 disabled

0 0

Al3 non-latch, Al4 non-latch

0 1

Al3 latch, Al4 non-latch

1 0

Al3 non-latch, Al4 latch

1 1

Al3 latch, Al4 latch

0 0 Relay3 On when Al3 active, Relay4 On when Al4 active

0 1 Relay3 Off when Al3 active, Relay4 On when Al4 active

1 0 Relay3 On when Al3 active, Relay4 Off when Al4 active

1 1 Relay3 Off when Al3 active, Relay4 Off when Al4 active