Laurel Electronics Custom ASCII Protocol For Laureate Series 2 Digital Panel Meters, Counters, Timers & L-Series Transmitters User Manual

Page 22

background image

22

REQUEST COUNTER VALUES

All active items 1, 2 or 3

*1B0

Item 1

*1B1

Item 2

*1B2

Item 3

*1B3

Peak

*1B4

Displayed item

*1B5

Valley

*1B6

All active items + Peak + Valley *1B7

RESET FUNCTIONS, DPM & SCALE METER

Cold reset

*1C0 Reads NVMEM into RAM locations after RAM is zeroed.

Latched alarms reset

*1C2

Peak value reset

*1C3

Remote display reset

*1C4

External Input B true

*1C5

External Input B false

*1C6

External Input A true

*1C7

External Input A false

*1C8

Valley reset

*1C9

Tare function

*1CA

Tare reset

*1CB

RESET FUNCTIONS, COUNTER / TIMER

Cold reset

*1C0 Reads NVMEM into RAM locations after RAM zeroed.

Function reset

*1C1 Resets all total values and/or peak value.

Latched alarms reset

*1C2

Peak value reset

*1C3

Remote display reset

*1C4 Resets Item 3 to zero if not Arith or Batch.

Removes Alarm View or Peak View if on.

External Input B true

*1C5

External Input B false

*1C6

External Input A true

*1C7

External Input A false

*1C8

Valley value reset

*1C9

Store totals & reset

*1CA


9.3 READING AND WRITING TO RAM AND NONVOLATILE MEMORY

CHARACTERS 1, 2

The Recognition character and Meter Address Code are the same as shown in previous table.