Laurel Electronics Custom ASCII Protocol For Laureate Series 2 Digital Panel Meters, Counters, Timers & L-Series Transmitters User Manual
Page 48

48
12. APPENDIX C: WEIGHT METER MEMORY ADDRESSES
AND DATA DEFINITIONS
12.1 WEIGHT METER 1-BYTE RAM MEMORY DATA
(L) = Lower memory, (U) = Upper memory
The bit assignments below constitute an 8-digit binary number, which needs to be converted
to Hex using a program such a Scientific Calculator under MS Windows Accessories. To
change an Item in Counter
/
Timer RAM Memory, write the converted Hex value to the Hex
Address shown in the left column. To change an Item in Nonvolatile Memory, go to table 11.3,
read the existing two-byte word (MS byte and LS byte) from the Counter
/
Timer for the Hex
Address which includes the Item to be changed, edit the MS or LS byte as appropriate, and
write the edited word back to the Hex Address.
Hex Address
Item Name
Bit Assignment
2D (L)
Setup
Bit 7 6 5 4 3 2 1 0 EXT IN A
EXT IN B BOTH
0 0 0 0 Meter Reset Meter Hold Cold
0 0 0 1 Funct Reset Peak Disp
Cold
0 0 1 0 Meter Hold Peak Disp
Func
0 0 1 1 Meter Hold Tare
Tare
0 1 0 0 Peak Disp
Tare
Func
0 1 0 1 Meter Reset Tare
Cold
0 1 1 0 Funct Reset Tare
Cold
0 1 1 1 Tare Reset
Tare
Cold
1 0 0 0 Disp Blank
Tare
Cold
1 0 0 1 Meter Reset Disp Blank
Cold
1 0 1 0 Funct Reset Disp Blank
Cold
1 0 1 1 Disp Item
Tare
Tare
1 1 0 0 Disp Item
Disp Blank
Func
1 1 0 1 Meter Reset Disp Item
Cold
1 1 1 0 Funct Reset Disp Item
Cold
1 1 1 1 Meter Hold Disp Item
Cold
0
Scale Using Scale, Offset
1
Scale Coord of 2 Points Method
0
Peak Key Action Displays Peak
1
Peak Key Action Displays Tare
0
Noise Cancellation for 60 Hz
1
Noise Cancellation for 50 Hz
0
4-1/2 Digits, No Dummy Zero
1
4-1/2 Digits Plus Dummy Zero