6.2 FRONT PANEL SETUP, COUNTERS & TIMERS ONLY

Press Menu
Select Key

Press Digit Select
Key

Press Value Select Key

___000

Output filtering

0

Send unfiltered signal

1

Send filtered signal

___000U

Baud rate

0

300 baud

4

4800 baud

1

600 baud

5

9600 baud

2

1200 baud

6

19200 baud

3

2400 baud

.

Ser 1

.

Serial Setup 1.
Press

until

Ser 1

is displayed.

Fixed Parameters
- No parity
- 8 data bits
- 1 stop bit

___000U

Output update rate,
Continuous Data Output
Mode.

60 Hz

50 Hz

0

0.017 sec

0.020 sec

1

0.28 sec

0.34 sec

2

0.57 sec

0.68 sec

3

1.1 sec

1.4 sec

4

2.3 sec

2.7 sec

5

4.5 sec

5.4 sec

6

9.1 sec

10.9 sec

7

18.1 sec

21.8 sec

8

36.6 sec

43.5 sec

9

72.5 sec

97 sec

__0000U

Line feed

0

No after

1

after

__0000U

Alarm data with readings

0

No alarm data

1

Alarm data with reading

__0000U

Control of data output

0

Continuous data output

1

Data output on ASCII command only

.

Ser 2

.

Serial Setup 2

__0000U

Meter address with Custom
ASCII protocol

Select

1

thru

F

for addresses 1 thru 15.

Select

0.

thru

F.

(with decimal point) for

addresses 16 thru 31.

.

Ser 3

.

Serial Setup 3

_00000U

RS485 half or full duplex

0

Full duplex

1

Half duplex

_00000U

Special start & stop char.
(entered using Instrument
Setup Software)

0

Standard continuous mode

1

Special start & stop characters