background image

- 25 -

For the following, use any starting Register Addresses and any number of Registers.

Register Addr

Dec

Hex

Register Name

Data

Type

Scaling & Decimal Point

49
50
51
52
53
54
55
56
57
58
50

0031
0032
0033
0034
0035
0036
0037
0038
0039

003A
003B

GateTime
TimeOut
Pulses
Total B (Hi word)
Total B (Mid word)
Total B (Lo word)
Total A (Hi word)
Total A (Mid word)
Total A (Lo word)
Cutoff
Calibration

M16
M16
M16
M48
M48
M48
M48
M48
M48
M16
M15

1-19999 (4E1F) Dec Pt =XXX.XX
1-19999 (4E1F) Dec Pt =XX.XXX
1-59999 (4E1F) Dec Pt =XXXXX.






0-65535
SXXX XXXX XXXX XXXX
Sign + Magnitude (PPM)

Data Type B16

Register Addr

Dec

Hex

Register

Name

Bit Significance

65

0041 Alarm

Config 1

Bit 0

0 = AL1 Hi Active

1 = Lo Active

Bit 1

0 = AL1 Enabled,

1 = Disabled

Bit 2

0 = AL2 Hi Active

1 = Lo Active

Bit 3

0 = AL2 Enabled

1 = Disabled

Bit 4

0 = AL1 Non-Latched 1 = Latched

Bit 5

0 = AL2 Non-Latched

1 = Latched

Bit 6

0 = Relay1 Active On

1 = Off

Bit 7

0 = Relay2 Active On

1 = Off

66

0042 Alarm

Config 2

Bits 2:0 # Readings before Alarms 1 & 2.

000 = 1, 001 = 2, 010 = 4, 011 = 8, 100 = 16,

101 = 32, 110 = 64, 111 = 128

Bits 4:3 Setpoint Compare Source
Bit 3

AL1 0 = Deviation

1 = Hysteresis

Bit 4

AL2 0 = Deviation

1 = Hysteresis

Bit 5

0 = Deviation in Menu 1 = Omitted

67

0043 Alarm

Config 3

Bit 0

0 = AL3 Hi Active

1 = Lo Active

Bit 1

0 = AL3 Enabled

1 = Disabled

Bit 2

0 = AL4 Hi Active

1 = Lo Active

Bit 3

0 = AL4 Enabled

1 = Disabled

Bit 4

0 = AL3 Non-Latched 1 = Latched

Bit 5

0 = AL4 Non-Latched 1 = Latched