beautypg.com

Features, Specifications – Controlled Products Systems Group E-9643-4B190Q User Manual

Page 3

background image

ENFORCER Long-Range Barrier Sensors

SECO-LARM U.S.A., Inc.

3

Features:

Specifications:

Model

E-9626-2B190Q

E-9643-4B190Q E-9661-6B190Q E-9679-8B190Q

Number of beams

2 pairs

4 pairs

6 pairs

8 pairs

Max. range (outdoor)

190’ (60m)

Max. range (indoor)

380’ (120m)

Tx standby & active current,
heater off

(+/-25%@12VDC)

56mA

84mA

100mA

109mA

Rx standby current (buzzer
off),heater off

(+/-25%@12VDC)

66mA

80mA

95mA

108mA

Rx trigger current (buzzer on)

heater off

(+/-25%@12VDC)

66mA

80mA

95mA

108mA

Buzzer active current

(Rx only)

20mA@12VDC

Heater active current

(Rx+Tx)

160mA@12VDC

Input voltage

12~24 VDC

Response time (receiver)

150/300/450/600 ms (DIP switch programmable)

Detection methods

Triggers as programmed when any 2 adjacent pair of beams are broken, or any

single pair of beams is broken for over 2 sec. (programmable by JP2)

Selectable beam frequencies

4 Different frequencies (DIP switch programmable)

Alarm output

NO/NC/COM, relay output, active for 1 sec. when triggered

Tamper output (Tx & Rx)

1A@120VAC / 1A@24VDC

Alignment LED (Rx only)

Red LED, ON – beam is broken / OFF – aligned

Alignment angle

Horizontal +/-90

O

Operating temperature

-45

O

C~55

O

C (-49

O

F~131

O

F)

Humidity

95%

Ingress protection

IP65

Case

Aluminum housing / PC anti-UV cover / ABS end caps

Dimensions

See page 4, Dimensions for more details

Weight (Tx & Rx) with brackets

5.5lb (2.5kg)

7.7lb (3.5kg)

12.1lb (5.5kg)

14.3lb (6.5kg)

For indoor or outdoor perimeter security

Long sensor range up to 190ft (60m)

outdoors, 380ft (120m) indoors

Install on windows, doorways, skylights,
fence tops, and any place where space

is limited

End caps swivel so sensor can be

mounted on a single wall or on opposite

walls with no L-bracket needed

Programmable immediate trigger on

simultaneous breaking of beams, or trigger

after a single pair of beams is broken for at

least 2 seconds

Heater for use in cold weather operation

Heater activates at 41°F (5°C)

Terminal block wiring

Slim design: 2

1

/

4

” x 1

7

/

8

” (55 x 49 mm)

Rugged aluminum construction

Built-in tamper switches, one on either end,

trigger the alarm if end cap is removed

No synchronizing wires required to align the
beams

Form C relay output

LED and buzzer alignment indicators

AGC (Auto Gain Control) circuits regulate

beam signals in order to compensate for
and ensure operation in rain, fog, and low-

temperature conditions

Programmable for 4 different frequencies to

reduce interference between

multiple units

This manual is related to the following products: