FAAC MODEL 844 Slide Gate Operator

Display

Function

Default

Display

Function

Default

OPENING PHOTOCELLS LOGIC:

Select the tripping mode of the opening photo-

cells.
They operate for the opening movement only:

they stop the movement and restart it when they

are released, or they reverse it immediately.

= Reverse immediately to closing

= Restart movement on release

ENCODER:
If the encoder is present, you may enable its

use.
If the encoder is present and enabled, "decele-

rations" and "partial opening" are controlled by

it (see relevant paragraphs).
The encoder operates as an anti-crushing de-

vice. If the gate hits an obstacle during opening

or closing, the encoder immediately reverses

the gate leaf movement for 2 seconds. If the

encoder operates again during the 2-seconds

reversing time, the movement stops (STOP)

without commanding any reversing.
If no encoder is supplied, the parameter must

be set to

. If there is the encoder, adjust

the sensitivity of the anti-crushing system,

by varying the parameter between

(maximum sensitivity) and

(minimum

sensitivity).

From

to

= Encoder active and sen-

sitivity adjustment

= Encoder disabled

Note 1: To reset the programming default settings, check

that the edge input is closed (SAFE LED ON), and

simultaneously press keys

+, - and F, holding them

down for 5 seconds.

Note 2: Modifications of programming parameters take

effect immediately, whereas changes are saved to

memory only after you exit programming and return

to normal gate status viewing. If the equipment is

powered down before returning to status viewing,

any modifications will be lost.

Pre-limit switch DECELERATION:

You can select gate deceleration before the

opening and closing limit-switches have been

tripped.
Time can be adjusted from

to

in

0.1-second steps.
If an encoder is used, the adjustment is not

determined by time but by motor revs, thus

obtaining greater deceleration precision.

= Deceleration disabled

From

to

= Deceleration enabled

Post-limit switch DECELERATION:

You can select gate deceleration after the

opening and closing limit-switches have been

tripped.
Time can be adjusted from

to

in

0.1-second steps.
If an encoder is used, the adjustment is not

determined by time but by motor revs, thus

obtaining greater deceleration precision.

= Deceleration disabled

from

to

= Deceleration enabled

ASSISTANCE REQUEST (combined

with next function):

If activated, at the end of countdown (see the

next function: "Cycle Programming") it effects

2 sec. (in addition to the value already set with

the PF function) of pre-flashing at every Open

pulse (job request). It can be useful to set

scheduled maintenance jobs.

= Active

= Disabled

WORK TIME (time-out):

It is advisable to set a value of 5 to 10 seconds

over the time taken by the gate to travel from

the closing limit-switch to the opening limit-

switch and vice versa.
Adjustable from to

sec. in one-second

steps.
Subsequently, display changes to minutes and

tens of seconds (separated by a point) and

time is adjusted in 10 second steps, up to a

maximum value of

minutes.

Attention: the set value will not exactly

match the motor's maximum operating time

if decelerations are used.

PARTIAL OPENING:

You can adjust the width of partial leaf opening.

Time can be adjusted from

to

in

1-second steps.

If an encoder is used, the adjustment is not

determined by time but by motor revs, thus

obtaining greater partial-opening precision. For

example, with pinion Z20, partial opening can

vary from 2' to 13'.

CYCLE PROGRAMMING:

To set countdown of system operation cycles.

Settable (in thousands) from

to

thousand cycles.

The displayed value is updated as cycles

proceed.

GATE STATUS:
Exit from programming, save data and return

to viewing gate status (see Section 5.5.1.).