FAAC MODEL 844 Slide Gate Operator

F

RP

Fig. 38

Fig. 39

TX -FSW - Negative for Power Supply to Photocell

Transmitters (Terminal 11)

If you use this terminal to connect the negative transmitters

of the photocell power, you may, if necessary, also use the

FAIL SAFE function (see advanced programming in Section

5.5.2).
If this function is enabled, the equipment checks operation of

the photocells before every opening or closing cycle.

A.A. - Power Supply to Audio Alarm (Terminal 12)

Connect a 24 VDC - 125mA max audio alarm compliant with

UL325. 31.1.4. The alarm will sound upon two sequential ac-

tivations of an entrapment protection device, continuosly until

the activation of a STOP command. To comply with UL325

the STOP input must be connected to a wired control located

in the line-of-sight of the gate.

5.4.5.

J2 Connector - Rapid Connection to RP

This is used for rapid connection of RP receivers (see Fig.

38). Fit the accessory with the components side toward

connector J1. Insert and remove after cutting power.

5.4.6.

J5 Connector - Rapid Connection to Capacitor

Quick-fit connector for connecting the motor starting

capacitor.

5.4.7.

Double Connector J8 - Limit-Switch Quick Fit

Quick-fit connector for connecting the limit-switch. For

connecting both the MLS magnetic limit-switch and the

inductive limit-switch (Fig. 23 Ref. ) to the operator.

5.5. PROGRAMMING

To program operation of the automated system, access the

"PROGRAMMING" mode with keys

F,+ and - on the cover.

Attention: before attempting to power up the system,

re-position the board's cover to avoid contact with high

voltage parts and to access the push-button keys on the

cover (Fig. 39).

BASIC PROGRAMMING

Display

Function

Default

FUNCTION LOGICS (see table of logics):

= Automatic

= "Stepped" automatic

= "Safety" Automatic
= Semi-automatic

= "Stepped" Semi-automatic

= Dead-man
= "B" Semi-automatic

= Mixed Log. (B opening / C closing)

PAUSE TIME:

This has effect only if automatic logic

was selected.
Adjustable from to

sec. in one-

second steps.
Subsequently, display changes to minu-

tes and tens of seconds (separated by a

point) and time is adjusted in 10-second

steps, up to the maximum value of

minutes.
E.g. if the display shows

, pause

time is 2 min. and 50 sec.

5.5.1.

BASIC PROGRAMMING

To access BASIC PROGRAMMING, press key

F:

• If you press it (and hold it down), the display shows the name of

the first function.

• If you release the key, the display shows the value of the function

that can be modified with keys

+ and -.

• If you press

F again (and hold it down), the display shows the

name of the next function, etc.

• When you reach the last function, press

F to exit the program,

and the display resumes showing the gate status.

The following table shows the sequence of functions

accessible in BASIC PROGRAMMING:

Programming is divided in two parts:

BASIC and ADVANCED.

+

-

F