beautypg.com

Advanced programming – Controlled Products Systems Group 109837 User Manual

Page 17

background image

17

FAAC MODEL 844 Slide Gate Operator

F

+

+

FORCE:
Adjusts Motor thrust.

= minimum force
= maximum force

OPENING DIRECTION:
Indicates the gate opening movement

and makes it possible not to change the

motor connections on the terminal board.

= Rightward opening movement

= Leftward opening movement

STATUS OF AUTOMATED SYSTEM:

Exit from programming, save data, and

return to gate status viewing.

= Closed

= Now opening

= At "STOP"

= Open

= Pause

= "FAIL SAFE" tripped

= Now closing

= Now reversing

= Photocells tripped

Display

Function

Default

Display

Function

Default

Display

Function

Default

5.5.2.

ADVANCED PROGRAMMING

To access ADVANCED PROGRAMMING, press key

F and,

as you hold it down, press key

+:

• If you release key

+ , the display indicates the name of the first

function.

• If you release key

F too, the display shows the value of the

function that can be modified with keys

+ and -.

• If you press key

F (and hold it down), the display shows the

name of the next function, and if you release it, the value that

can be modified with keys

+ and - is shown.

• When you reach the last function, press

F to exit the program,

and the display resumes showing the gate status.

The following table shows the sequence of functions

accessible in ADVANCED PROGRAMMING:

ADVANCED PROGRAMMING

MAXIMUM TORQUE AT INITIAL THRUST:

The motor operate at maximum torque (igno-

ring the torque setting) at start of movement.
Useful for heavy leaves.

= Active

= Disabled

FINAL BRAKING:

When the gate reaches the opening or
closing limit-switch, a braking stroke can be
selected to ensure the leaf is stopped imme-
diately. If decelerations are selected, braking
starts when they finish.
At

value, braking is disabled.

Time can be adjusted from

to

in

0.01-second steps.

= Braking disabled

from

to

= Timed braking

FAIL SAFE:

If this function is activated, it enables a function

test of the photocells before any gate move-

ment. If the test fails (photocells not working are

indicated by the value

on the display), the

gate does not start moving.

= Active

= Disabled

PRE-FLASHING (5 s):

Activates the flashing lamp for 5 seconds before
start of movement.

= Disabled

= Only before opening

= Only before closing

= Before every movement

CLOSING PHOTOCELLS LOGIC:

Select the tripping mode of the closing photo-

cells.
They operate for the closing movement only:

they stop movement and reverse it when they

are released, or they reverse it immediately.

= Reverse on release

= Reverse immediately to opening

RESERVED:

Fixed to

This manual is related to the following products: