beautypg.com

45 5 d c, Ont r ol, Ane l – Controlled Products Systems Group 1044182 User Manual

Page 21: Ns ta ll a t io n, Nstructions, Advanced programming

background image

Page 2 1

M a y, 20 06
4 1 5 L LS Ope ra tor A nd
4 5 5 D C ontrol Pa ne l I nsta ll a ti on Ma nua l

T

HE

45
5 D C

ONT

R

OL

P

ANE

L

I

NS
TA
LL

A

T

IO

N

I

NSTRUCTIONS

F

AIL

S

AFE

:

If this function is activated, it en-

ables a function test of the photo-

cells before any gate movement.

If the test fails (photocells not

serviceable), the gate does not

start the movement.

Y = Enable

No = Disabled

P

RE

F

LASHING

(5

S

):

Activates the flashing lamp for 5s

before start of movement.

Y = Enable

No = Disabled

E

LECTRIC

L

OCK

ON

L

EAF

2:

For using the electric lock on leaf 2

instead of on leaf 1.

Y = Enable

No = Disabled

Display Function Default

I

NDICATOR

-L

ICHT

:

If 0 is selected, the output func-

tions as a standard indicator-light

(lighted at opening and pause,

flashing at closing, and off when

gate closed). Different figures

correspond to timed activation of

the output, which can be used (via

a relay) to power a courtesy lamp.

Time can be adjusted from 0 to

59s in 1s increments, and from

1.0 to 4.1 min. in 10s steps.

0 = Standard Indicator-Light

From 1 to 4.1 = Timed Output

C

LOSING

P

HOTOCELLS

REVERSE

AT

RELEASE

:

Enable this function if

you want the closing photocells to

stop the gate movement and re-

verse it after the beam is cleared.

Default setting is immediate re-

verse.

Y = Enable

No = Disabled

A.D.M.A.P. F

UNCTION

:

If this function is enabled, the

safety devices operate in compli-

ance with French standard NFP

25/362.

Y = Enable

No = Disabled

A

DVANCED

P

ROGRAMMING

To access ADVANCED PROGRAMMING, press the “F” key
and, as you hold it down, press the “+” key:

If you release the “+”, the display indicates the name
of the first function.

If you release the “F” key, too, the display shows the
value of the function that can be modified with keys

“+” and “—”.

If you press the “F” key (and hold it down), the dis-
play shows the name of the next function, and if

you release it, the value that can be modified with

keys “+” and “—”.

When you reach the last function, press the “F” key
to exit the program, and the display resumes show-

ing the status of the inputs.

The table on page 21 and 22 shows the sequence of

functions accessible in

ADVANCED

PROGRAMMING.

ADVANCED PROGRAMMING

+

Display Function

Default

M

AXIMUM

T

ORQUE

AT

I

NITIAL

T

HRUST

:

The motors operate

at maximum torque (ignoring

the torque setting) at start of

movement. Useful for heavy

leaves.

Y = Enable

No = Disabled

L

AST

S

TROKE

AT

C

LOSING

:

The motors are activated at full

speed for 1s to facilitate lock-

ing of the electric lock.

Y = Enable

No = Disabled

R

EVERSING

S

TROKE

:

Before opening, while the gate

is closed, the motors thrust to

close for 2 s thus facilitating

release of the electric lock.

Y = Enable

No = Disabled

L

EAF

2 O

PENING

D

ELAY

(2

S

):

Enables delayed start (at open-

ing) of leaf 2, avoiding interfer-

ence between leaves.

Y = Enable

No = Disabled

F

+