beautypg.com

455 d c, Ont r ol, Ane l – Controlled Products Systems Group 1044182 User Manual

Page 18: Nst a ll at ion

background image

E (semi-automatic):

This mode requires a

command to open and a command to close.

A second command during opening stops the

gate. A second command during closing

reopens the gate.

EP (semi-automatic, step by step):

This

mode requires a command to open and a

command to close. A second command

during opening or closing causes the gate to

stop. A third command then reverses the

previous motion of the gate.

B (manned, pulsed):

This mode is designed

for guard station use and requires a three-

button switch (pulsed) to open, close, and

stop the gate.

C (manned and constant):

This mode

requires constant pressure switches. One to

open and one to close. No pressure on a

switch stops the gate.

• AP (stepped automatic):

The gate opens

on command and automatically closes after a

pause phase. A second command while

opening is ignored; a second command

during the pause phase interrupts the pause

time; a second command during closing

reopens the gate. A maintained open

command will NOT hold the gate open.

The three programming push buttons allow the

programming of the torque (or pressure), the pause

time between opening and closing, and the leaf delay

on closing.

WARNING!

Turn the main power off before you

make any electrical connections.

For all FAAC hydraulic operators using the 455 D

control panel, the force must be set at its maximum
setting of 50 in order to supply the correct voltage to

the operator.

P

AUSE

T

IME

:

The pause time between opening and

closing can be adjusted from 0 seconds to 4 minutes.

Time is adjusted in one-second increments from 0—

59 seconds. When 60 seconds is reached, time is

adjusted in 10 second increments up to 4 minutes.

i.e. if display shows 2.5, it means 2 minutes and 50

seconds.

L

EAF

D

ELAY

:

You may choose to delay one leaf on

closing for overlapping gate leaves. Be sure the

operator on the leaf for delayed closing is connected

to Motor 1. On opening, the leaf connected to Motor 2

is delayed 2.5 sec.

N

OTE

: If an opening leaf delay is desired, it must

be enabled in the Advance Programming.

opening and closing, respectively, are triggered. Use

the LEDs and the next table to determine if the

accessory devices you have installed are operating

properly.

Electric Locks: An electric lock can be wired to
the 455 D in

terminals 18 and 21 (12Vac pulsed

provided). If a reversing stroke is needed to allow the

electric lock to release, this must be done in advanced

programming.

See page 19 for the connections for a magnetic locking

device.

W

ARNING

L

IGHT

:

Connect a warning light to

terminals 18 and 20 in the group labeled W.LIGHT

in terminal block J1 and J5. The terminals provide

an output voltage of 24 VDC, maximum power 3

Watts. This output voltage will power most 24 VDC

warning lights.

N

OTE

: The behavior of the warning light varies

according to the logic you have set.

L

OGICS

A, S, E, EP, AP

AND

B:

The warning light is on

steadily during opening and the pause phase. During

closing, the light flashes.

L

OGIC

C:

The warning light is on steadily during

opening and flashes during closing.

S

ET

O

THER

O

PERATING

C

ONTROLS


WARNING

! Turn the main power off before you

make any electrical connections.

You need to program the control panel for your gate's

operation. The 455 D Control Panel has on board

programming that controls a wide range of functions.

O

PERATING

L

OGICS

N

OTE

: The 455 D Control Panel provides inputs

for opening reversing devices and closing

reversing devices. FAAC strongly recommends

the use of reversing devices, such as photocells

or other non-contact sensors.

A (automatic):

The gate opens on command

and automatically closes after a pause phase. A

second command while opening is ignored; a

second command during the pause phase

interrupts the pause time; a second command

during closing reopens the gate. A maintained

open command will hold the gate open.

S (security):

The security mode is like A logic

except that a second command during opening

immediately closes the gate. A maintained

open command will not hold the gate open.

Page 1 8

M a y, 20 06

4 1 5 L LS Ope ra tor And

4 5 5 D C ontrol Pa ne l I nsta ll a ti on Ma nua l

T

HE

455 D C

ONT

R

OL

P

ANE

L

I

NST

A

LL

AT

ION

I

NS

T

R

U

C

T

IO

N

S