However, if enabled, you cannot adjust this

opening delay of the operator connected to

Motor 2.

The closing leaf-delay time is adjustable from 0 to

4 minutes.

N

OTE

:

If the opening/closing time is set at

less than the leaf delay time, the delayed leaf

closes at the end of the closing time.

P

ROGRAMMING

To program the automated system, the

“Programming Mode” must be accessed.

Programming is split into two parts: BASIC and

ADVANCED.

R

ESTORE

THE

D

EFAULT

S

ETTINGS

To restore the default settings of the programming

press the three program buttons (+, —, F )

simultaneously and keep them pressed for five (5)

seconds.

B

ASIC

P

ROGRAMMING

To access BASIC PROGRAMMING, press the “F” key.

If you press it (and hold it down), the display
shows the name of the first function.

If you release the key, the display shows the
value of the function that can be modified with

keys + and — .

If you press and hold down the “F” key again
(and hold it down), the display shows the

name of the next function, etc.

When you reach the last function, press “F” to
exit the program, and the display resumes

showing the status of the inputs.

The table on the right shows the sequence of

functions accessible in BASIC PROGRAMMING.

BASIC PROGRAMMING

Display Function

Default

O

PERATING

L

OGICS

A = Automatic (Timer to Close)

E = Semi Automatic

S = Security

EP = (Semi-Automatic) Step by Step

AP = Stepped Automatic

B = Manned, Pulsed

C = Manned, constant

P

AUSE

T

IME

This is the time between open and

closing and is adjustable from 0 to

4 min. This is only true in “A”

Mode. (see pause time description)

F

ORCE

/T

ORQUE

M

OTOR

1

This adjusts the force / torque that

motor 1 is applying to the gate

leaf. Setting is 0 to 50.*

F

ORCE

/T

ORQUE

M

OTOR

2

This adjusts the force / torque that

motor 2 is applying to the gate

leaf. Setting is 0 to 50.*

C

LOSING

L

EAF

D

ELAY

Delays the closing of operator

wired into motor one outputs. Ad-

justable from 0 to 4 minutes

(Same as pause time)

M

OTOR

R

UN

T

IME

This enables where you choose

from “simple” learning or

“complete” learning of the motor

run time. See page 10 & 11 for

complete details.

Simple Learning

~ 1 s.

Complete Learning


> 3 s.

E

XIT

P

ROGRAMMING

Exit from programming and return

to display of inputs status.

+

F

+

* With Hydraulic operators the Force/Torque must be set to
the maximum setting of 50.

PROGRAM BUTTONS

+ -