CTI Products MCN RCD System Planner User Manual
Page 43
Appendix C System Examples
MCN Comparator Display System Planner
Page 39
This system allows parallel status and control of three comparators from three operator locations. If an
operator at one location force votes a receiver, the other two operator stations will show that receiver as
voted. Or, if an operator disables a receiver, all other operator stations will also show that receiver as
disabled. If one of the comparators signals that a receiver is voted, all three stations will show the
receiver being voted.
Equipment List for Example System 4
Item Model/Option
Description
Qty
1
S2-60433
IIB I/O Interface Module
3
2
S2-60442
CIB Comparator Interface Module
3
3
S1-60424
Host Computer Interface Module (HIB) with MCN
Remote Comparator Display DOS Software for Local
and Dial-Up PC
2
Order Separately PCs for Local and Dial-Up display **
2
4
S2-60441
Serial Cable Kit (includes cable and adapter for 9 pin
or 25 pin communication ports) for local HIB
1
5
S2-60445
Serial Cable for HIB to Modem
for Dial-Up HIB
1
6
99-10962
V.34 Dial-Up Modems
2
7
S2-60450
PC (9 or 25 pin) - Modem 6’ Serial Cable
1
8
S2-60437
DIGITAC Bracket and Cable Kit
1
9
S2-60435
Quad Rack Mount Size A
(1) for Spectra-TAC CIBs, (1) for extended IIBs
2
10
S2-60436
Wall Mount Kit
(For mounting HIB in console electronics room)
1
11
89-10837
Cable Assy 25 pr M-M 25'
for IIBs
3
12
89-10843
Male to Blunt Cable 25’
for Spectra-TAC Comparators
2
13
31-10354
Punch Block, 50-Pair (for IIBs)
2
14
S2-60438
Cable Assy Network 9"
(1) Dial-up HIB to Spectra-TAC CIB
(1) Spectra-TAC CIB to Spectra-TAC CIB
(2) IIB to IIB
4
15
89-10732
3’ Network Cable
Quad rack mount to Digitac CIB
1
16
89-10835
25’ Network Cable
HIB in CEB room to IIB Quad rack mount
1
17
S2-60538
1000 Ft Network Cable
DIGITAC Comparator CIB Module to HIB in console
electronics room
1
18
S2-60318
Network Terminator
2
19
81-10398
Power Supply N. American
(2) needed to power (8) modules
2
There is one limitation of a system which uses both HIBs and IIBs together to control the same
comparator. The console Disable LED can get out of sync if the PC re-enables a receiver. See the
Appendix E System Limitations when using HIB and IIB Modules Together section for details.