MCN Comparator Display System Planner

Page 39

This system allows parallel status and control of three comparators from three operator locations. If an
operator at one location force votes a receiver, the other two operator stations will show that receiver as
voted. Or, if an operator disables a receiver, all other operator stations will also show that receiver as
disabled. If one of the comparators signals that a receiver is voted, all three stations will show the
receiver being voted.

Equipment List for Example System 4

Item Model/Option

Description

Qty

1

S2-60433

IIB I/O Interface Module

3

2

S2-60442

CIB Comparator Interface Module

3

3

S1-60424

Host Computer Interface Module (HIB) with MCN
Remote Comparator Display DOS Software for Local
and Dial-Up PC

2

Order Separately PCs for Local and Dial-Up display **

2

4

S2-60441

Serial Cable Kit (includes cable and adapter for 9 pin
or 25 pin communication ports) for local HIB

1

5

S2-60445

Serial Cable for HIB to Modem
for Dial-Up HIB

1

6

99-10962

V.34 Dial-Up Modems

2

7

S2-60450

PC (9 or 25 pin) - Modem 6’ Serial Cable

1

8

S2-60437

DIGITAC Bracket and Cable Kit

1

9

S2-60435

Quad Rack Mount Size A
(1) for Spectra-TAC CIBs, (1) for extended IIBs

2

10

S2-60436

Wall Mount Kit
(For mounting HIB in console electronics room)

1

11

89-10837

Cable Assy 25 pr M-M 25'
for IIBs

3

12

89-10843

Male to Blunt Cable 25’
for Spectra-TAC Comparators

2

13

31-10354

Punch Block, 50-Pair (for IIBs)

2

14

S2-60438

Cable Assy Network 9"
(1) Dial-up HIB to Spectra-TAC CIB
(1) Spectra-TAC CIB to Spectra-TAC CIB
(2) IIB to IIB

4

15

89-10732

3’ Network Cable
Quad rack mount to Digitac CIB

1

16

89-10835

25’ Network Cable
HIB in CEB room to IIB Quad rack mount

1

17

S2-60538

1000 Ft Network Cable
DIGITAC Comparator CIB Module to HIB in console
electronics room

1

18

S2-60318

Network Terminator

2

19

81-10398

Power Supply N. American
(2) needed to power (8) modules

2

There is one limitation of a system which uses both HIBs and IIBs together to control the same
comparator. The console Disable LED can get out of sync if the PC re-enables a receiver. See the